enow.com Web Search

  1. Ads

    related to: ceiling fan cfm chart for winter heat and air compressor system design

Search results

  1. Results from the WOW.Com Content Network
  2. Axial fan design - Wikipedia

    en.wikipedia.org/wiki/Axial_fan_design

    An axial fan is a type of fan that causes gas to flow through it in an axial direction, parallel to the shaft about which the blades rotate. The flow is axial at entry and exit. The flow is axial at entry and exit.

  3. Actual cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Actual_cubic_feet_per_minute

    Actual cubic feet per minute (ACFM) is a unit of volumetric flow. It is commonly used by manufacturers of blowers and compressors. [1] This is the actual gas delivery with reference to inlet conditions, whereas cubic foot per minute (CFM) is an unqualified term and should only be used in general and never accepted as a specific definition without explanation.

  4. Ceiling fan - Wikipedia

    en.wikipedia.org/wiki/Ceiling_fan

    A pendulum fan or flap fan is a type of low velocity ceiling fan that can be used for air circulation around a targeted area. The back and forth motion increases turbulence around cooling sources, like chilled waterfalls at the Lavin Bernick Center at Tulane, helping to cool a greater volume of air. Brushed DC ceiling fans.

  5. Cooling load - Wikipedia

    en.wikipedia.org/wiki/Cooling_load

    The cooling load [3] is calculated to select HVAC equipment that has the appropriate cooling capacity to remove heat from the zone. A zone is typically defined as an area with similar heat gains, similar temperature and humidity control requirements, or an enclosed space within a building with the purpose to monitor and control the zone's temperature and humidity with a single sensor e.g ...

  6. Thermal destratification - Wikipedia

    en.wikipedia.org/wiki/Thermal_destratification

    Because axial destratification fans can achieve destratification with low CFMs, it is imperative that the air leaving the nozzle achieve an air speed at the floor of between 0.2 and 0.5 m/s. The result of this level of air movement is the integration of conditioned air from the ceiling with air at the floor level.

  7. Displacement ventilation - Wikipedia

    en.wikipedia.org/wiki/Displacement_ventilation

    The density difference between cold air and warm air creates upward convective flows known as thermal plumes. Instead of working as a stand-alone system in interior space, displacement ventilation system can also be coupled with other cooling and heating sources, such as radiant chilled ceilings [4] or baseboard heating. [1]