enow.com Web Search

  1. Ad

    related to: peritoneal dialysis charting guidelines 1

Search results

  1. Results from the WOW.Com Content Network
  2. Standardized Kt/V - Wikipedia

    en.wikipedia.org/wiki/Standardized_Kt/V

    Standardized Kt/V, also std Kt/V, is a way of measuring dialysis adequacy. It was developed by Frank Gotch and is used in the United States to measure dialysis. Despite the name, it is quite different from Kt/V. In theory, both peritoneal dialysis and hemodialysis can be quantified with std Kt/V.

  3. Kt/V - Wikipedia

    en.wikipedia.org/wiki/Kt/V

    For a US perspective, see the KDOQI clinical practice guidelines [10] and for a United Kingdom perspective see: U.K. Renal Association clinical practice guidelines [11] According to the US guidelines, for thrice a week dialysis a Kt/V (without rebound) should be 1.2 at a minimum with a target value of 1.4 (15% above the minimum values). However ...

  4. Renal replacement therapy - Wikipedia

    en.wikipedia.org/wiki/Renal_replacement_therapy

    Renal replacement therapy includes dialysis (hemodialysis or peritoneal dialysis), hemofiltration, and hemodiafiltration, which are various ways of filtration of blood with or without machines. Renal replacement therapy also includes kidney transplantation , which is the ultimate form of replacement in that the old kidney is replaced by a donor ...

  5. Peritoneal dialysis - Wikipedia

    en.wikipedia.org/wiki/Peritoneal_dialysis

    Peritoneal dialysis (PD) is a type of dialysis that uses the peritoneum in a person's abdomen as the membrane through which fluid and dissolved substances are exchanged with the blood. [ 1 ] [ 2 ] It is used to remove excess fluid, correct electrolyte problems , and remove toxins in those with kidney failure . [ 3 ]

  6. Urea reduction ratio - Wikipedia

    en.wikipedia.org/wiki/Urea_reduction_ratio

    In continuous hemodialysis or in peritoneal dialysis, for example, a considerable amount of dialysis is delivered, but the urea level remains roughly constant after the initial treatment of uremia, so the URR is essentially zero. In long slow overnight dialysis, if simplified equations are used, the URR also underestimates the amount of ...

  7. ICD-10 Procedure Coding System - Wikipedia

    en.wikipedia.org/wiki/ICD-10_Procedure_Coding_System

    The ICD-10 Procedure Coding System (ICD-10-PCS) is a US system of medical classification used for procedural coding.The Centers for Medicare and Medicaid Services, the agency responsible for maintaining the inpatient procedure code set in the U.S., contracted with 3M Health Information Systems in 1995 to design and then develop a procedure classification system to replace Volume 3 of ICD-9-CM.

  8. Hemodialysis product - Wikipedia

    en.wikipedia.org/wiki/Hemodialysis_product

    Hemodialysis product (HDP) - is a number used to quantify hemodialysis and peritoneal dialysis treatment adequacy. It was proposed by Scribner and Oreopoulous because of their perceived inadequacy of the Kt/V measure of dialysis adequacy. The HDP is defined by the following empirical formula: HDP = t * f 2. Where: HDP - hemodialysis product

  9. Talk:Peritoneal dialysis - Wikipedia

    en.wikipedia.org/wiki/Talk:Peritoneal_dialysis

    Peritoneal dialysis is a continuous therapy, meaning it is designed to work all day, every day. Peritoneal dialysis has been used as a treatment option for ESKD since the 1960s. At the end of 2004, there were more than 1,300,000 patients on dialysis worldwide, with 11% being treated with peritoneal dialysis. [1]

  1. Ad

    related to: peritoneal dialysis charting guidelines 1