Logo of Eurocode 2 An example of a concrete structure. In the Eurocode series of European standards (EN) related to construction, Eurocode 2: Design of concrete structures (abbreviated EN 1992 or, informally, EC 2) specifies technical rules for the design of concrete, reinforced concrete and prestressed concrete structures, using the limit state design philosophy.
All of the EN Eurocodes relating to materials have a Part 1-1 which covers the design of buildings and other civil engineering structures and a Part 1-2 for fire design. The codes for concrete, steel, composite steel and concrete, and timber structures and earthquake resistance have a Part 2 covering design of bridges.
Reinforced concrete structures are normally designed according to rules and regulations or recommendation of a code such as ACI-318, CEB, Eurocode 2 or the like. WSD, USD or LRFD methods are used in design of RC structural members. Analysis and design of RC members can be carried out by using linear or non-linear approaches.
For example, in Europe, structures are designed to conform with the Eurocodes: Steel structures are designed in accordance with EN 1993, and reinforced concrete structures to EN 1992. Australia, Canada, China, France, Indonesia, and New Zealand (among many others) utilise limit state theory in the development of their design codes.
The overall mass of concrete can be reduced by 35–50% depending on the design, [1] as a consequence of reduced slab mass, as well as lower requirements for vertical structure and foundations. Biaxial slabs commonly span up to 20 metres at a thickness of around 500 mm. [ citation needed ] The added strength also reduces the acoustic ...
It has now been replaced by the Structural Eurocodes for the design of steel and concrete structures. The standard specifies the requirements and the code of practice [ 1 ] [ 2 ] on design of steel , [ 1 ] concrete ( reinforced , prestressed or composite) [ 2 ] and composite bridges that use steel sections (rolled or fabricated, cased or ...
BS 8110 is a withdrawn British Standard for the design and construction of reinforced and prestressed concrete structures. It is based on limit state design principles. Although used for most civil engineering and building structures, bridges and water-retaining structures are covered by separate standards (BS 5400 and BS 8007).
EN 1994-1-2 deals with the design of composite steel and concrete structures for the accidental situation of fire exposure and is intended to be used in conjunction with EN 1994-1-1 and EN 1991-1-2. This part only identifies differences from, or supplements to, normal temperature design and deals only with passive methods of fire protection.