enow.com Web Search

  1. Ad

    related to: boiler feed water treatment process flow chart

Search results

  1. Results from the WOW.Com Content Network
  2. Boiler feedwater - Wikipedia

    en.wikipedia.org/wiki/Boiler_feedwater

    Boiler feedwater is the water which is supplied to a boiler. The feed water is put into the steam drum from a feed pump. In the steam drum the feed water is then turned into steam from the heat. After the steam is used, it is then dumped to the main condenser. From the condenser, it is then pumped to the deaerated feed tank.

  3. Oxygenated treatment - Wikipedia

    en.wikipedia.org/wiki/Oxygenated_treatment

    Less flow resistance, lower dissolved feedwater iron concentrations, FeOOH film is more stable, reduced boiler cleaning frequency - Disadvantages: Increased risk of FAC, a deaerator is required, more frequent chemical cleaning is required, hazardous chemicals (hydrazine) are used. A deaerator is required. Air leakage is more serious.

  4. Boiler water - Wikipedia

    en.wikipedia.org/wiki/Boiler_water

    Boiler water is liquid water within a boiler, or in associated piping, pumps and other equipment, that is intended for evaporation into steam.The term may also be applied to raw water intended for use in boilers, treated boiler feedwater, steam condensate being returned to a boiler, or boiler blowdown being removed from a boiler.

  5. Industrial water treatment - Wikipedia

    en.wikipedia.org/wiki/Industrial_water_treatment

    Internal treatment within the boiler is focused on limiting the tendency of water to dissolve the boiler, and maintaining impurities in forms least likely to cause trouble before they can be removed from the boiler in boiler blowdown. Deaerator is used to reduce oxygen and nitrogen in boiler feed water applications.

  6. Deaerator - Wikipedia

    en.wikipedia.org/wiki/Deaerator

    The boiler feedwater is sprayed into section where it is preheated by the rising steam from the sparger. The purpose of the feedwater spray nozzle and the preheat section is to heat the boiler feedwater to its saturation temperature to facilitate stripping out the dissolved gases in the following deaeration section. The preheated feedwater then ...

  7. Thermal power station - Wikipedia

    en.wikipedia.org/wiki/Thermal_power_station

    The feed water cycle begins with condensate water being pumped out of the condenser after traveling through the steam turbines. The condensate flow rate at full load in a 500 MW plant is about 6,000 US gallons per minute (400 L/s). Diagram of boiler feed water deaerator (with vertical, domed aeration section and horizontal water storage section).

  8. Boiler feedwater pump - Wikipedia

    en.wikipedia.org/wiki/Boiler_feedwater_pump

    A boiler feedwater pump is a specific type of pump used to pump feedwater into a steam boiler.The water may be freshly supplied or returning condensate produced as a result of the condensation of the steam produced by the boiler.

  9. Boiler (power generation) - Wikipedia

    en.wikipedia.org/wiki/Boiler_(power_generation)

    Feed water for boilers needs to be as pure as possible with a minimum of suspended solids and dissolved impurities which cause corrosion, foaming and water carryover. The most common options for demineralization of boiler feedwater are reverse osmosis (RO) and ion exchange (IX). [6]

  1. Ad

    related to: boiler feed water treatment process flow chart