enow.com Web Search

  1. Ad

    related to: dry cooling tower design calculation

Search results

  1. Results from the WOW.Com Content Network
  2. Cooling tower - Wikipedia

    en.wikipedia.org/wiki/Cooling_tower

    Most adiabatic cooling towers are also hybrid cooling towers. Dry cooling towers (or dry coolers) are closed circuit cooling towers which operate by heat transfer through a heat exchanger that separates the working coolant from ambient air, such as in a radiator, utilizing convective heat transfer. They do not use evaporation and are air-cooled ...

  3. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The first of the cooling load factors used in this method is the CLTD, or the Cooling Load Temperature Difference. This factor is used to represent the temperature difference between indoor and outdoor air with the inclusion of the heating effects of solar radiation. [1] [5] The second factor is the CLF, or the cooling load factor.

  4. Cooling load - Wikipedia

    en.wikipedia.org/wiki/Cooling_load

    The cooling load [3] is calculated to select HVAC equipment that has the appropriate cooling capacity to remove heat from the zone. A zone is typically defined as an area with similar heat gains, similar temperature and humidity control requirements, or an enclosed space within a building with the purpose to monitor and control the zone's temperature and humidity with a single sensor e.g ...

  5. Coefficient of performance - Wikipedia

    en.wikipedia.org/wiki/Coefficient_of_performance

    The coefficient of performance or COP (sometimes CP or CoP) of a heat pump, refrigerator or air conditioning system is a ratio of useful heating or cooling provided to work (energy) required. [1] [2] Higher COPs equate to higher efficiency, lower energy (power) consumption and thus lower operating costs. The COP is used in thermodynamics.

  6. Rankine cycle - Wikipedia

    en.wikipedia.org/wiki/Rankine_cycle

    Cooling towers operate as large heat exchangers by absorbing the latent heat of vaporization of the working fluid and simultaneously evaporating cooling water to the atmosphere. While many substances can be used as the working fluid, water is usually chosen for its simple chemistry, relative abundance, low cost, and thermodynamic properties .

  7. Evaporative cooler - Wikipedia

    en.wikipedia.org/wiki/Evaporative_cooler

    For arid climates with a great wet-bulb depression, cooling towers can provide enough cooling during summer design conditions to be net zero. For example, a 371 m 2 (4,000 ft 2 ) retail store in Tucson, Arizona with a sensible heat gain of 29.3 kJ/h (100,000 Btu/h) can be cooled entirely by two passive cooling towers providing 11890 m 3 /h ...

  8. Underfloor air distribution - Wikipedia

    en.wikipedia.org/wiki/Underfloor_air_distribution

    The tool requires users to specify the zone cooling load and the fraction of the cooling load assigned to the underfloor plenum. It also requires users to input the supply air temperature either at the diffuser or at the duct but with the ratio of plenum flowrate to zonal supply flowrate.

  9. Frederik van Iterson - Wikipedia

    en.wikipedia.org/wiki/Frederik_van_Iterson

    [4] [5] This design of cooling towers was the world's first, and nearly all cooling towers now follow this hyperboloid design, with concrete structure. On 16 August 1916, he took out the UK patent (108,863) for Improved Construction of Cooling Towers of Reinforced Concrete; [6] the patent was filed on 9 August 1917, and published on 11 April 1918.

  1. Ad

    related to: dry cooling tower design calculation