One review of tall buildings suggests that residential towers may have 3.1 m (10 ft 2 in) floor height for apartments, while a commercial building may have floor height of 3.9 m (12 ft 9.5 in) for the storeys leased to tenants. In such tall buildings (60 or more storeys), there may be utility floors of greater height. [7]
This does not include light rail systems that follow the BOStrab standard, with newer metro lines to use low-floor trams which have a usual floor height of 300 to 350 mm (11.8 to 13.8 in) so that platforms are constructed as low as 300 mm in accordance with BOStrab that requires the platform height not to be higher than the floor height. [20]
A floor plan is not a top view or bird's-eye view; it is a measured drawing to scale of the layout of a floor in a building. A top view or bird's-eye view does not show an orthogonally projected plane cut at the typical four foot height above the floor level. A floor plan may show any of the following elements: [3] interior walls and hallways ...
Elevation view of the Panthéon, Paris principal façade Floor plans of the Putnam House. A house plan [1] is a set of construction or working drawings (sometimes called blueprints) that define all the construction specifications of a residential house such as the dimensions, materials, layouts, installation methods and techniques.
The old standard North American passenger railcar is 10 ft 6 in (3.20 m) wide by 14 ft 6 in (4.42 m) high and measures 85 ft 0 in (25.91 m) over coupler pulling faces with 59 ft 6 in (18.14 m) truck centers, or 86 ft 0 in (26.21 m) over coupler pulling faces with 60 ft 0 in (18.29 m) truck centers.
A mezzanine (/ ˌ m ɛ z ə ˈ n iː n /; or in Italian, a mezzanino) [1] is an intermediate floor in a building which is partly open to the double-height ceilinged floor below, or which does not extend over the whole floorspace of the building, a loft with non-sloped walls. However, the term is often used loosely for the floor above the ground ...
Space between the structural ceiling and the dropped ceiling or under a raised floor is typically considered plenum; however, some drop-ceiling designs create a tight seal that does not allow for airflow and therefore may not be considered a plenum air-handling space. [1] [2]
The CU value should be obtained by the manufacturer of the luminaire which is to be evaluated. In order to determine the CU on the manufacturer's table, a room cavity ratio (RCR) must be used. Also, the reflectance of the ceiling, walls and floor must be known. RCR = 5 x (room height) x (room width + room length) / [(room width) x (room length ...