Search results
Results from the WOW.Com Content Network
Number of chest X-rays resulting in same effective dose Skull radiography (X-ray) 0.015 1 Chest X-ray 0.013 1 Lumbar spine X-ray 0.44 30 Abdomen X-ray 0.46 35 Pelvis X-ray 0.48 35 Screening mammography (4 views) 0.2 15 Dental X-ray (intraoral) 0.013 1 Diagnostic fluoroscopy: barium swallow 1 70 Cardiac angiography 7 500 Head CT 2 150 Chest CT 10
The application of radiation can aid the patient by providing doctors and other health care professionals with a medical diagnosis, but the exposure of the patient should be reasonably low enough to keep the statistical probability of cancers or sarcomas (stochastic effects) below an acceptable level, and to eliminate deterministic effects (e.g ...
Example representation of the environmental factors characterizing the exposome. The exposome is a concept used to describe environmental exposures that an individual encounters throughout life, and how these exposures impact biology and health. It encompasses both external and internal factors, including chemical, physical, biological, and ...
The exposure caused by potassium-40 present within a normal person. The exposure to the ingestion of a soluble radioactive substance, such as 89 Sr in cows' milk. A person who is being treated for cancer by means of a radiopharmaceutical where a radioisotope is used as a drug (usually a liquid or pill). A review of this topic was published in ...
Early on it was found that X-rays, gamma rays, and beta radiation were essentially equivalent for all cell types. Therefore, the standard radiation type X is generally an X-ray beam with 250 keV photons or cobalt-60 gamma rays. As a result, the relative biological effectiveness of beta and photon radiation is essentially 1.
An x-ray image receptor, containing an anti-scatter grid and three AEC regions (represented by dark grey circles and square) These regions represent anatomical areas, e.g. lungs, spine. They can be selected individually, or all at once depending on the need. Automatic Exposure Control (AEC) is an X-ray exposure termination
Diagnosis is typically made based on a history of significant radiation exposure and suitable clinical findings. [3] An absolute lymphocyte count can give a rough estimate of radiation exposure. [3] Time from exposure to vomiting can also give estimates of exposure levels if they are less than 10 Gy (1000 rad). [3]
When an exposure is made, X-ray radiation exits the tube as what is known as the primary beam. When the primary beam passes through the body, some of the radiation is absorbed in a process known as attenuation. Anatomy that is denser has a higher rate of attenuation than anatomy that is less dense, so bone will absorb more X-rays than soft tissue.