The coefficient of performance or COP (sometimes CP or CoP) of a heat pump, refrigerator or air conditioning system is a ratio of useful heating or cooling provided to work (energy) required. [1] [2] Higher COPs equate to higher efficiency, lower energy (power) consumption and thus lower operating costs. The COP is used in thermodynamics.
Cooling capacity is the measure of a cooling system's ability to remove heat. [1] It is equivalent to the heat supplied to the evaporator/boiler part of the refrigeration cycle and may be called the "rate of refrigeration" or "refrigeration capacity".
Both the COP of a refrigerator and a heat pump can be greater than one. Combining these two equations results in: = + for fixed values of Q H and Q L. This implies that COP HP will be greater than one because COP R will be a positive quantity. In a worst-case scenario, the heat pump will supply as much energy as it consumes, making it act as a ...
No work is required to move the displacer since, ideally there is no pressure drop over it. Typically its motion is 90 degrees out of phase with the piston. In the ideal case the COP also equals to the Carnot COP. Another type of Stirling cooler is the split-pair type (Fig.4), consisting of a compressor, a split pipe, and a cold finger.
You are free: to share – to copy, distribute and transmit the work; to remix – to adapt the work; Under the following conditions: attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses ...
Food in a refrigerator with its door open. A refrigerator, commonly shortened to fridge, is a commercial and home appliance consisting of a thermally insulated compartment and a heat pump (mechanical, electronic or chemical) that transfers heat from its inside to its external environment so that its inside is cooled to a temperature below the room temperature. [1]
Schematic diagram of a cryogen-free, or dry, dilution refrigerator precooled by a two-stage pulse tube refrigerator, indicated by the dotted rectangle. A 3 He/ 4 He dilution refrigerator is a cryogenic device that provides continuous cooling to temperatures as low as 2 mK, with no moving parts in the low-temperature region.
A refrigeration system's coefficient of performance (CoP) is very important in determining a system's overall efficiency. It is defined as refrigeration capacity in kW divided by the energy input in kW. While CoP is a very simple measure of performance, it is typically not used for industrial refrigeration in North America.