  1. Results from the WOW.Com Content Network
  2. Bus coupler - Wikipedia

    en.wikipedia.org/wiki/Bus_coupler

    Even if only one non-terminated coupler acts as the bus because all devices (bus controller, remote terminals, etc.) are connected to the coupler stubs, the external bus connections of the coupler must be terminated. A dual-terminated coupler (with or without non-functional bus connectors) can be employed where the coupler acts as the bus ...

  3. MIL-STD-1553 - Wikipedia

    en.wikipedia.org/wiki/MIL-STD-1553

    A single bus consists of a wire pair with 70–85 Ω impedance at 1 MHz. Where a circular connector is used, its center pin is used for the high (positive) Manchester bi-phase signal. Transmitters and receivers couple to the bus via isolation transformers, and stub connections branch off using a pair of isolation resistors and, optionally, a ...

  4. Electrical termination - Wikipedia

    en.wikipedia.org/wiki/Electrical_termination

    The MIL-STD-1553B bus must be terminated at both ends to minimize the effects of signal reflections that can cause waveform distortion and disruption or intermittent communications failures. Optionally, a high-impedance terminator (1000 to 3000 ohms) may be used in vehicle applications to simulate a future load from an unspecified device.

  5. Parallel SCSI - Wikipedia

    en.wikipedia.org/wiki/Parallel_SCSI

    Diagrams of different Parallel SCSI symbols [1]. Parallel SCSI is not a single standard, but a suite of closely related standards. There are a dozen SCSI interface names, most with ambiguous wording (like Fast SCSI, Fast Wide SCSI, Ultra SCSI, and Ultra Wide SCSI); three SCSI standards, each of which has a collection of modular, optional features; several different connector types; and three ...

  6. DIN 41612 - Wikipedia

    en.wikipedia.org/wiki/DIN_41612

    DIN 41612 was a DIN standard for electrical connectors that are widely used in rack based electrical systems. Standardisation of the connectors is a pre-requisite for open systems, where users expect components from different suppliers to operate together. The most widely known use of DIN 41612 connectors is in the VMEbus and NuBus systems.

  7. RS-485 - Wikipedia

    en.wikipedia.org/wiki/RS-485

    RS-485 does not specify any connector or pinout. Circuits may be terminated on screw terminals, D-subminiature connectors, or other types of connectors. The standard does not discuss cable shielding but makes some recommendations on preferred methods of interconnecting the signal reference common and equipment case grounds.

  8. NMEA 2000 - Wikipedia

    en.wikipedia.org/wiki/NMEA_2000

    The NMEA 2000 network, like the SAE J1939 network on which it is based, is organized around a bus topology, and requires a single 120Ω termination resistor at each end of the bus. (The resistors are in parallel, so a properly terminated bus should have a total resistance of 60Ω). The maximum distance for any device from the bus is six metres.

  9. Twinaxial cabling - Wikipedia

    en.wikipedia.org/wiki/Twinaxial_cabling

    Twinax is a bus topology that requires termination to function properly. Most twinax T-connectors have an automatic termination feature. For use in buildings wired with Category 3 or higher twisted pair there are baluns that convert Twinax to twisted pair and hubs that convert from a bus topology to a star topology. Twinax was designed by IBM.