  2. Duct leakage testing - Wikipedia

    en.wikipedia.org/wiki/Duct_leakage_testing

    Duct leakage test in the US. A duct leakage tester is a diagnostic tool designed to measure the airtightness of forced air heating, ventilating and air-conditioning (HVAC) ductwork. A duct leakage tester consists of a calibrated fan for measuring an air flow rate and a pressure sensing device to measure the pressure created by the fan flow.

  3. Blower door - Wikipedia

    en.wikipedia.org/wiki/Blower_door

    Duct leakage testing of forced air heating/cooling systems - both supply (vents) ducts and return ducts can be tested to determine if and how much they leak air. A duct test can be combined with a blower door test to measure the total leakage to outside, measuring effective leakage to the outside of the house only.

  4. Testing, adjusting, balancing - Wikipedia

    en.wikipedia.org/wiki/Testing,_adjusting,_balancing

    In heating, ventilation, and air conditioning (HVAC), testing, adjusting and balancing (TAB) are the three major steps used to achieve proper operation of heating, ventilation, and air conditioning systems. TAB usually refers to commercial building construction and the specialized contractors who employ personnel that perform this service.

  5. Ductwork airtightness - Wikipedia

    en.wikipedia.org/wiki/Ductwork_airtightness

    The relationship between pressure and leakage air flow rate is defined by the power law model between the airflow rate and the pressure difference across the ductwork envelope as follows: q L =C L ∆p n. where: q L is the volumetric leakage airflow rate expressed in L.s −1; C L is the air leakage coefficient expressed in L.s −1.Pa −n

  6. Air Movement and Control Association - Wikipedia

    en.wikipedia.org/wiki/Air_Movement_and_Control...

    Two Water Test Facilities with chambers capable of simulating eight inches (203 mm) of rain-fall per hour and wind speeds of 50 mph (80 km/h). Multi Nozzle Chambers that are capable of measuring airflow up to 88,000 cfm. Circulator Fan Facility capable of testing 96 inch fans. Acoustic Duct Silencer Facility; ISO/IEC 17025 accredited

  7. Section 608 - Wikipedia

    en.wikipedia.org/wiki/Section_608

    An initial verification test must then be done within 30/120 days, and then a follow-up test within 10 days of that. There are additional clauses for extensions if needed. If the leak is not to be repaired, there must be a plan to retire or retrofit the appliance within 30 days, to be completed within one year. [10]

  8. Infiltration (HVAC) - Wikipedia

    en.wikipedia.org/wiki/Infiltration_(HVAC)

    Infiltration is sometimes called air leakage. The leakage of room air out of a building, intentionally or not, is called exfiltration . Infiltration is caused by wind , negative pressurization of the building, and by air buoyancy forces known commonly as the stack effect .

  9. Glossary of HVAC terms - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_HVAC_terms

    1. Components made of multiple smaller blades, sometimes adjustable, placed in ducts or duct entries to control the volume of air flow. When used inside of ducts, their function is similar to that of a damper, but they can be manufactured to fit larger openings than a single-piece damper. 2.