The main standard that governs fire pump fixed-place installations in North America is the National Fire Protection Association's NFPA 20 Standard for the Installation of Stationary Fire Pumps for Fire Protection. [1] Fire pumps are powered most commonly by an electric motor or a diesel engine, or, occasionally a steam turbine.
Multi-story buildings equipped with fire sprinkler systems may require a large booster pump to deliver sufficient water pressure and volume to upper floors in the event of a fire. Such pumps are often powered by a diesel engine dedicated to this purpose. The engine needs a fuel tank and an automatic controller that will start the booster pump ...
Variable Speed Fire Pump Controllers were invented and released with a UL Listing for fire pump service in 2003 by Master Control Systems, Inc. [1] [2] Paragraph 10.5.5 in the 2003 edition of NFPA-20 recognized Variable Speed as an accepted method for operating the fire pump. Then in the NFPA-20 2007 edition, section 10.10 was added to clarify ...
A drawing which based on the detailed drawing, installation drawing or co-ordination drawing (interface drawing) with the primary purpose of defining that information needed by the tradesmen on site to install the works or concurrently work among various engineering assembly. The main features of typical installation drawings are:
Waterous Company is an American manufacturer of fire pumps, hydrants and fire suppression equipment. Based in South St Paul, Minnesota. [1] Originally part of Waterous Engine Works Co. Ltd, the fire equipment operation in Winnipeg was relocated to St Paul, Minnesota in 1886 [2] [3]
These were pump vehicles extensively used by the auxiliary fire service during the cold war and called upon to relieve the firemen's strikes in the 1970s and 1980s. The portable pumps later became diesel powered, and trailer mounted versions were also available. A new development in 1971 was the Godiva UMP pump.
Engineered fire suppression systems are design specific and most commonly used for larger installations where the system is designed for a particular application. Examples include large marine and land vehicle applications, server rooms, public and private buildings, industrial paint lines, dip tanks and electrical switch rooms.
External access point for fire sprinkler and dry standpipe at a building in San Francisco, US Antique wet standpipe preserved at Edison and Ford Winter Estates. A standpipe or riser is a type of rigid water piping which is built into multi-story buildings in a vertical position, or into bridges in a horizontal position, to which fire hoses can be connected, allowing manual application of water ...