enow.com Web Search

  1. Ads

    related to: well pressure switch 30/50 or 40/60 1/2 ton

Search results

  1. Results from the WOW.Com Content Network
  2. Oil well control - Wikipedia

    en.wikipedia.org/wiki/Oil_well_control

    The pressure gradient is described as the pressure per unit length. Often in oil well control, pressure exerted by fluid is expressed in terms of its pressure gradient. The SI unit is pascals/metre. The hydrostatic pressure gradient can be written as: Pressure gradient (psi/ft) = HSP/TVD = 0.052 × MW (ppg). [12]

  3. Pressure switch - Wikipedia

    en.wikipedia.org/wiki/Pressure_switch

    The contacts of the pressure switch may be rated a few tenths of an ampere to around 15 amperes, with smaller ratings found on more sensitive switches. Often a pressure switch will operate a relay or other control device, but some types can directly control small electric motors or other loads.

  4. Pressure tank - Wikipedia

    en.wikipedia.org/wiki/Pressure_tank

    Case 2 is a tank in use, with the air pressure at pressure P (gauge) and a water volume of V. Referring to the diagram on the right, a pressure tank is generally pressurized when empty with a "charging pressure" P c, which is usually about 2 psi below the turn-on pressure P lo (Case 1). The total volume of the tank is V t.

  5. Safety valve - Wikipedia

    en.wikipedia.org/wiki/Safety_valve

    An oxygen safety relief valve DN250-safety valves. A safety valve is a valve that acts as a fail-safe.An example of safety valve is a pressure relief valve (PRV), which automatically releases a substance from a boiler, pressure vessel, or other system, when the pressure or temperature exceeds preset limits.

  6. Ground glass joint - Wikipedia

    en.wikipedia.org/wiki/Ground_glass_joint

    Crude versions of conically tapered ground glass joints have been made for quite a while, [1] particularly for stoppers for glass bottles and retorts. [2] Crude glass joints could still be made to seal well by grinding the two parts of a joint against each other using an abrasive grit, but this led to variations between joints and they would not seal well if mated to a different joint.

  7. GE 45-ton switcher - Wikipedia

    en.wikipedia.org/wiki/GE_45-ton_switcher

    4 ft 8 + 12 in (1,435 mm) Minimum curve: 50 ft (15.24 m) Loco weight: 43 to 50 short tons (38 to 45 long tons; 39 to 45 t) Prime mover: two Cummins HBI-600 or 855NTC diesels in later models: RPM range: 1,800 rpm (max) Aspiration: Normally aspirated: Displacement: 672 cubic inches (11 L) or 855 cubic inches (14 L) Traction motors: Two, one ...

  1. Ads

    related to: well pressure switch 30/50 or 40/60 1/2 ton