The CLTD/CLF/SCL (cooling load temperature difference/cooling load factor/solar cooling load factor) cooling load calculation method was first introduced in the 1979 ASHRAE Cooling and Heating Load Manual (GRP-158) [1] The CLTD/CLF/SCL Method is regarded as a reasonably accurate approximation of the total heat gains through a building envelope ...
As the original technical software partner of ACCA, [3] Wrightsoft Corp became the first HVAC software company to create a computerized version of their Manual J, Manual D, and Manual N calculation methods. The Air Conditioning Contractors of America and Wrightsoft released the very first Manual J Load calculation software (Right-J) in February ...
The objective of building performance simulation is the quantification of aspects of building performance which are relevant to the design, construction, operation and control of buildings. [1] Building performance simulation has various sub-domains; most prominent are thermal simulation, lighting simulation, acoustical simulation and air flow ...
An enhanced electronic version, known as ASHRAE Handbook Online is a web-based version updated annually that contains the four latest volumes as well as extra content such as calculations, demonstration videos, and spreadsheets. The various versions of the Handbook are typically available to the public via technical, and other, libraries and ...
HVAC system design is a subdiscipline of mechanical engineering, based on the principles of thermodynamics, fluid mechanics, and heat transfer. "Refrigeration" is sometimes added to the field's abbreviation as HVAC&R or HVACR, or "ventilation" is dropped, as in HACR (as in the designation of HACR-rated circuit breakers).
The equation is: = | | where is the useful heat supplied or removed by the considered system (machine). > is the net work put into the considered system in one cycle. The COP for heating and cooling are different because the heat reservoir of interest is different.
The cooling load [3] is calculated to select HVAC equipment that has the appropriate cooling capacity to remove heat from the zone. A zone is typically defined as an area with similar heat gains, similar temperature and humidity control requirements, or an enclosed space within a building with the purpose to monitor and control the zone's temperature and humidity with a single sensor e.g ...
To reduce draft risk at temperatures below 22.5 °C (72.5 °F), air speed due to the HVAC system must be 0.15 m/s (30 ft/min) or below. The vertical air temperature difference between ankle and head is limited to 3 °C (5.4 °F) for seated occupants and 4 °C (7.2 °F) for standing occupants. [ 6 ]