The original GDF specification was introduced in 2005 as a new data format to overcome some of the limitations of the European Data Format for Biosignals (EDF). GDF was also designed to unify a number of file formats which had been designed for very specific applications (for example, in ECG research and EEG analysis). [2]
European Data Format (EDF) is a standard file format designed for exchange and storage of medical time series.Being an open and non-proprietary format, EDF(+) is commonly used to archive, exchange and analyse data from commercial devices in a format that is independent of the acquisition system.
Pronunciation follows convention outside the medical field, in which acronyms are generally pronounced as if they were a word (JAMA, SIDS), initialisms are generally pronounced as individual letters (DNA, SSRI), and abbreviations generally use the expansion (soln. = "solution", sup. = "superior").
The analog signal comprises a microvoltage time series of the EEG, sampled digitally and sampling rates adequate to over-sample the signal (using the Nyquist principle of exceeding twice the highest frequency being detected). Modern EEG amplifiers use adequate sampling to resolve the EEG across the traditional medical band from DC to 70 or 100 ...
An EEG recording setup using the 10-10 system of electrode placement. EEG is the gold standard diagnostic procedure to confirm epilepsy.The sensitivity of a routine EEG to detect interictal epileptiform discharges at epilepsy centers has been reported to be in the range of 29–55%. [8]
Emergency Medical Service(s) EMU: early morning urine sample (being the most concentrated, generally used for pregnancy testing) Emul: emulsion: ENT: ear, nose, and throat (see otolaryngology) EOB: edge of bed EoL: End-of-life (adjective) EoLC: End-of-life care: EOM: extraocular muscles: EOMI: extraocular movements intact (see eye movement) EPCT
EEG electrode positions in the 10-10 system using modified combinatorial nomenclature, along with the fiducials and associated lobes of the brain. When recording a more detailed EEG with more electrodes, extra electrodes are added using the 10% division , which fills in intermediate sites halfway between those of the existing 10–20 system.
A paper published in 2023 showed that burst suppression and epilepsy may share the same ephaptic coupling mechanism. [6] When inhibitory control is sufficiently low, as in the case of certain general anesthetics such as sevoflurane (due to a decrease in the firing of interneurons [7]), electric fields are able to recruit neighboring cells to fire synchronously, in a burst suppression pattern.