  2. Stack effect - Wikipedia

    en.wikipedia.org/wiki/Stack_effect

    There is a pressure difference between the outside air and the air inside the building caused by the difference in temperature between the outside air and the inside air. That pressure difference ( ΔP) is the driving force for the stack effect and it can be calculated with the equations presented below. [10] [11] The equations apply only to ...

  3. Positive pressure - Wikipedia

    en.wikipedia.org/wiki/Positive_pressure

    Positive pressure rooms are used for immunocompromised persons (eg. Neutropenic) whereby controlled quality air is sent into the room to prevent random (and potentially polluted) air from entering the room. [4] The CDC recommends a positive pressure differential of at least 2.5 Pa between the positively pressured room and the adjoining hallway. [5]

  4. Passive ventilation - Wikipedia

    en.wikipedia.org/wiki/Passive_ventilation

    Natural ventilation in buildings can rely mostly on wind pressure differences in windy conditions, but buoyancy effects can a) augment this type of ventilation and b) ensure air flow rates during still days. Buoyancy-driven ventilation can be implemented in ways that air inflow in the building does not rely solely on wind direction.

  5. Drain-waste-vent system - Wikipedia

    en.wikipedia.org/wiki/Drain-waste-vent_system

    Also, where positive drainage pressures are found in larger buildings or multi-story buildings, an air admittance valve could be used in conjunction with a positive pressure reduction device such as the PAPA positive air pressure attenuator to provide a complete venting solution for more complicated drainage venting systems.

  6. Building airtightness - Wikipedia

    en.wikipedia.org/wiki/Building_airtightness

    The relationship between pressure and leakage air flow rate is defined by the power law between the airflow rate and the pressure difference across the building envelope as follows: [16] q L =C L ∆p n. where: q L is the volumetric leakage airflow rate expressed in m 3 h −1; C L is the air leakage coefficient expressed in m 3 h −1 Pa −n

  7. Indoor air quality - Wikipedia

    en.wikipedia.org/wiki/Indoor_air_quality

    Commercial buildings, and sometimes residential, are often kept under slightly positive air pressure relative to the outdoors to reduce infiltration. Limiting infiltration helps with moisture management and humidity control. Dilution of indoor pollutants with outdoor air is effective to the extent that outdoor air is free of harmful pollutants.

  8. Blower door - Wikipedia

    en.wikipedia.org/wiki/Blower_door

    The blower door fan is used to blow air into or out of the building, creating either a positive or negative pressure differential between inside and outside. This pressure difference forces air through all holes and penetrations in the building enclosure.

  9. Ventilation (architecture) - Wikipedia

    en.wikipedia.org/wiki/Ventilation_(architecture)

    For residential buildings, which mostly rely on infiltration for meeting their ventilation needs, a common ventilation rate measure is the air change rate (or air changes per hour): the hourly ventilation rate divided by the volume of the space (I or ACH; units of 1/h). During the winter, ACH may range from 0.50 to 0.41 in a tightly air-sealed ...