Pure-tone audiometry is a subjective, behavioural measurement of a hearing threshold, as it relies on patient responses to pure tone stimuli. [3] Therefore, pure-tone audiometry is only used on adults and children old enough to cooperate with the test procedure.
"Conventional" pure tone audiometry (testing frequencies up to 8 kHz) is the basic measure of hearing status. [6] For research purposes, or early diagnosis of age-related hearing loss, ultra-high frequency audiograms (up to 20 kHz), requiring special audiometer calibration and headphones, can be measured. [7]
The standard and most common type of hearing test is pure tone audiometry, which measures the air and bone conduction thresholds for each ear in a set of 8 standard frequencies from 250Hz to 8000Hz. The test is conducted in a sound booth using either a pair of foam inserts or supraural headphones connected to an external audiometer.
The most common type of hearing test is pure tone audiometry (PTA). It charts the thresholds of hearing sensitivity at a selection of standard frequencies between 250 and 8000 Hz. There is also high frequency pure tone audiometry which tests frequencies from 8000 to 20,000 Hz.
Secondarily, as the tone may be absent (catch trial), "yes" is not always the correct answer. Finally, catch trials help to detect the amount of a listener's guessing. The main disadvantage lies in the large number of trials needed to obtain the data, and therefore time required to complete the test. [4] Method of adjustment
An audiologist conducting an audiometric hearing test in a sound-proof testing booth. Identification of a hearing loss is usually conducted by a general practitioner medical doctor, otolaryngologist, certified and licensed audiologist, school or industrial audiometrist, or other audiometric technician.
Schwabach test, a variant of the Rinne test; Pure tone audiometry is a standardized hearing test in which air conduction hearing thresholds in decibels (db) for a set of fixed frequencies between 250 Hz and 8,000 Hz are plotted on an audiogram for each ear independently. A separate set of measurements is made for bone conduction.
An individual with true hearing loss should continue to hear the sound on the better hearing side. Alternatively, this test can be performed more accurately using a two-channel audiometer using pure tone signals. [3] In this procedure, a tone is presented to the "good ear" at 10 to 20 dB SL (above the threshold level).