A humidistat has the functionality of a switch and is not just a measuring instrument like a hygrometer is. For heating, ventilation, and air conditioning (HVAC) of buildings, humidistats or humidity sensors are used to sense the air relative humidity in the controlled space and turn on and off the HVAC equipment. [3]
Between 45% and 55% RH, static builds up at reduced levels, while humidity above 55% RH ensures that static will never build up. [11] The American Society of Heating, Refrigerating and Air Conditioning Engineers has traditionally recommended a range of 45–55% RH in data centers to prevent sparks that can damage IT equipment. [12]
The equipment used can consist of machines used to remove heat such as a chiller or a cooling tower and equipment for adding heat to the building's water such as a boiler or a commercial water heater. Hydronic fan coil units can be generally divided into two types: Two-pipe fan coil units or four-pipe fan coil units. Two-pipe fan coil units ...
An air handler, or air handling unit (often abbreviated to AHU), is a device used to regulate and circulate air as part of a heating, ventilating, and air-conditioning system. [1] An air handler is usually a large metal box containing a blower , furnace or A/C elements, filter racks or chambers, sound attenuators , and dampers . [ 2 ]
A heat exchanger is the part of the system that transfers heat from the hot parts of the machine or a system to the cold parts of the machine or system. heat gain heat load heat loss Terms for the amount of cooling (heat gain) or heating (heat loss) needed to maintain desired temperatures and humidifies in controlled air.
The ASHRAE Handbook is the four-volume flagship publication of the nonprofit technical organization ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers [a]). This Handbook is considered the most comprehensive and authoritative repository of practical knowledge on the various topics that form the field of heating ...
Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!
The most common indoor pollutants monitored in DCV systems are carbon dioxide and humidity. [1] This control strategy is mainly intended to reduce the energy used by heating, ventilation, and air conditioning (HVAC) systems compared to those of buildings that use open-loop controls with constant ventilation rates.