The Underwriters Laboratories' UL 294 is a safety standard that addresses the construction, performance, and operation of access control systems intended to regulate or control entry into and exit from secured areas. These systems can also restrict access to certain devices through electrical, electronic, or mechanical means.
NFPA 80 allows a maximum door undercut of 3/4 inch, however fire doors are tested with smaller clearances in accordance with NFPA 252. [6] Corridors have a fire rating of one hour or less, and the fire doors in them are required by code to have a fire rating of 1/2 or 1/3 hour, the intent of which is mainly to restrict smoke travel. [7]
The Life Safety Code requires that the pressure differential across the barrier not be so great as to prevent the door from opening with a force of 30 lbf (133 N) at the door knob or handle. [4] These 'pressurization' problems are, of course, non-existent with naturally ventilated smokeproof enclosures.
Exit from the interior of a building to the fire escape may be provided by a fire exit door, but in most cases the only exit is through a window. When there is a door, it is often fitted with a fire alarm to prevent other uses of the fire escape, and to prevent unauthorized entry. As many fire escapes were built before the advent of electronic ...
The committee's initial report evolved into NFPA 13, Standard for the Installation of Sprinkler Systems, the most widely used fire sprinkler standard. [ 6 ] Around 1904, the NFPA began to expand its membership from affiliates of fire insurance companies to many other organizations and individuals, and also expanded its mission beyond ...
Remote annunciator: a device that connects directly to the panel; the annunciator's main purpose is to allow emergency personnel to view the system status and take command from outside the electrical room the panel is located in. Usually, annunciators are installed by the front door, the door the fire department responds by, or in a fire ...
A report by the UK-based Building Research Establishment (BRE) stated "there is a commonly held view that equipment designed to meet the European EN54 Fire detection and fire alarm systems standard cannot be used within an installation designed to the US National Fire Alarm Code, NFPA 72." In actuality, "there appears to be no requirement in ...
NFPA 101 - 7.10.3.1 requires textual exit signs for all standard mounted applications; pictograms are allowed instead of or in addition to text if approved by local authorities and compliant with NFPA 170. [6] The NFPA has also approved the ISO pictogram as an option for low-level glow-in-the-dark signs. [7]