  2. North American Fire Hose Coupler Incompatibilities - Wikipedia

    en.wikipedia.org/wiki/North_American_Fire_Hose...

    According to NFPA 1963, all U.S. fire hydrants should have the following ports: 2 + 1 ⁄ 2-inch attack port with 2.5-7.5 NH threads (two ports per hydrant; NFPA 1963 requirement) 4 + 1 ⁄ 2-inch pumper (steamer) port with either 4.5-4 NH threads or a 5-inch Storz port (one port per hydrant; NFPA 1963 requirement)

  3. Fire hydrant - Wikipedia

    en.wikipedia.org/wiki/Fire_hydrant

    A dry hydrant by Passumpsic River in rural Vermont. In rural areas where municipal water systems are not available, dry hydrants are used to supply water for fighting fires. A dry hydrant is analogous to a standpipe. A dry hydrant is usually an unpressurized, permanently installed pipe that has one end below the water level of a lake or pond.

  4. Glossary of firefighting equipment - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_firefighting...

    Dry hydrant A fire hydrant with a valve located at the bottom of the barrel, near the water main. The barrel of the hydrant remains dry until used. The prevents the hydrant from freezing in sub-zero temperatures. A dry hydrant is also an unpressurized pipe that can be used to draft (or draw) water from a pond or lake. Dry powders

  5. Variable speed fire pump controller - Wikipedia

    en.wikipedia.org/wiki/Variable_speed_fire_pump...

    Conserve Water During Testing – NFPA-25 requires that the fire pump controller is operated for 10 minutes each week. This ends up using a substantial amount of water in buildings that have static pressures greater than 175 PSI and relies on a system relief valve to control the pressure: (50–100% of the rating of the pump) × (10minutes) × ...

  6. Standpipe (firefighting) - Wikipedia

    en.wikipedia.org/wiki/Standpipe_(firefighting)

    External access point for fire sprinkler and dry standpipe at a building in San Francisco, US Antique wet standpipe preserved at Edison and Ford Winter Estates. A standpipe or riser is a type of rigid water piping which is built into multi-story buildings in a vertical position, or into bridges in a horizontal position, to which fire hoses can be connected, allowing manual application of water ...

  7. Wildland water tender - Wikipedia

    en.wikipedia.org/wiki/Wildland_water_tender

    A wildland water tender is a specialized vehicle capable of bringing water, foam, or dry chemicals to fire trucks in the field that are engaged on the fireline. Water tenders have a large truck mounted tank that carries a minimum 1,000 gallons and up to 4,000 gallons of water.

  8. Active fire protection - Wikipedia

    en.wikipedia.org/wiki/Active_fire_protection

    Standpipes are installed in most large, multistory buildings. There are two types of standpipes: dry and wet. Most standpipes are dry systems and cannot be used by the public. Dry systems require a fire engine to pump water into the system. Most dry systems do not have pre-connected hoses and require firefighters to bring in the hose.

  9. Fire sprinkler system - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler_system

    In regions using NFPA regulations, wet pipe systems cannot be installed unless the range of ambient temperatures remains above 40 °F (4 °C). [16] Water is not present in the piping until the system operates; instead, the piping is filled with dry air at a pressure below the water supply pressure.