Search results
Results from the WOW.Com Content Network
The test is carried out using a metal mould in the shape of a conical frustum known as a slump cone or Abrams cone, that is open at both ends and has attached handles.The tool typically has an internal diameter of 100 millimetres (3.9 in) at the top and of 200 millimetres (7.9 in) at the bottom with a height of 305 millimetres (12.0 in).The cone is placed on a hard non-absorbent surface.
The flow table test or slump-flow test is a method to determine consistency of fresh concrete. Flow table test is also used to identify transportable moisture limit of solid bulk cargoes. [ 1 ] It is used primarily for assessing concrete that is too fluid (workable) to be measured using the slump test , because the concrete will not retain its ...
Concrete Slump Test Dataset Concrete slump flow given in terms of properties. Features of concrete given such as fly ash, water, etc. 103 Text Regression 2009 [235] [236] I. Yeh Musk Dataset Predict if a molecule, given the features, will be a musk or a non-musk. 168 features given for each molecule. 6598 Text Classification 1994 [237]
Test methods for the water-cement ratio and fineness modulus). 1919 – Effect of Curing Condition on Wear and Strength of Concrete (Describing 120 tests on cylinder-shaped samples and 300 tests on cubic samples in various moisture conditions and testing periods varying from 3 days to 4 months).
ACI Code 7.10.4.2: For cast-in-place construction, size of spirals shall not be less than 3/8 in. diameter. ACI Code 7.10.4.3: Clear spacing between spirals shall not exceed 3 in., nor be less than 1in. Section 10.9.3 adds an additional lower limit to the amount of spiral reinforcement via the volumetric spiral reinforcement ratio ρ s.
Mass concrete is defined by American Concrete Institute Committee 207 as "any volume of concrete with dimensions large enough to require that measures be taken to cope with the generation of heat from the hydration of cement and attendant volume change to minimize cracking."
Ride on power trowels range in size from 1.8 m (6 ft) machines weighing 270–320 kg (600–700 lb), up to 3.7 m (12 ft) machines weighing over 910 kg (2,000 lb). Power ranges from small 10 kW (13 hp) single cylinder engines, all the way up to 70 kW (100 hp) multi fuel V8 engines.
Self-consolidating concrete or self-compacting concrete (SCC) [1] is a concrete mix which has a low yield stress, high deformability, good segregation resistance (prevents separation of particles in the mix), and moderate viscosity (necessary to ensure uniform suspension of solid particles during transportation, placement (without external compaction), and thereafter until the concrete sets).