enow.com Web Search

  1. Ad

    related to: electrical transformer sizing calculator formula 1

Search results

  1. Results from the WOW.Com Content Network
  2. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    In the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. . Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to t

  3. Transformer - Wikipedia

    en.wikipedia.org/wiki/Transformer

    In electrical engineering, a transformer is a passive component that transfers electrical energy from one electrical circuit to another circuit, or multiple circuits.A varying current in any coil of the transformer produces a varying magnetic flux in the transformer's core, which induces a varying electromotive force (EMF) across any other coils wound around the same core.

  4. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    Center-tapped delta transformer Center-tapped delta transformer voltages. High-leg delta service is supplied in one of two ways. One is by a three-phase transformer (or three single-phase transformers), having four wires coming out of the secondary, the three phases, plus a neutral connected as a center-tap on one of the windings.

  5. Zigzag transformer - Wikipedia

    en.wikipedia.org/wiki/Zigzag_transformer

    For example, an electrical network may have a transmission network of 110 kV/33 kV star/star transformers, with 33 kV/11 kV delta/star for the high voltage distribution network. If a transformation is required directly between the 110 kV/11 kV network an option is to use a 110 kV/11 kV star/delta transformer.

  6. Distribution transformer - Wikipedia

    en.wikipedia.org/wiki/Distribution_transformer

    A single-phase wye transformer usually has only one bushing on top, connected to one of the three primary phases. The other end of the primary winding is connected to the transformer case, which is connected to the neutral wire of the wye system and is also grounded. A wye distribution system is preferred because the transformers present ...

  7. Buck–boost transformer - Wikipedia

    en.wikipedia.org/wiki/Buck–boost_transformer

    Buck–boost transformers can be used to power low voltage circuits including control, lighting circuits, or applications that require 12, 16, 24, 32 or 48 volts, consistent with the design's secondaries. The transformer is connected as an isolating transformer and the nameplate kVA rating is the transformer’s capacity. [2]

  8. Stacking factor - Wikipedia

    en.wikipedia.org/wiki/Stacking_factor

    Stacking factors are typically 0.95 or higher for transformer cores [4] and machine stators. [5] However, cores made from amorphous metal have a stacking factor of around 0.8, compared to 0.96 for silicon steel. [1] A related concept in transformer design is window space factor. This is defined as the ratio of the area occupied by the copper ...

  9. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    For example, if the imbalance is limited to 25% of the total load (half of one half) rather than the absolute worst-case 50%, then conductors 3/8 of the single-phase size will guarantee the same maximum voltage drop, totalling 9/8 of one single-phase conductor, 56% of the copper of the two single-phase conductors.

  1. Ad

    related to: electrical transformer sizing calculator formula 1