enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Ultraviolet photoelectron spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Ultraviolet_photoelectron...

    With this source, Turner's group obtained an energy resolution of 0.02 eV. Turner referred to the method as "molecular photoelectron spectroscopy", now usually "ultraviolet photoelectron spectroscopy" or UPS. As compared to XPS, UPS is limited to energy levels of valence electrons, but measures them more accurately.

  3. Ultraviolet–visible spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Ultraviolet–visible...

    UV-Vis can be used to monitor structural changes in DNA. [8] UV-Vis spectroscopy is routinely used in analytical chemistry for the quantitative determination of diverse analytes or sample, such as transition metal ions, highly conjugated organic compounds, and biological macromolecules. Spectroscopic analysis is commonly carried out in ...

  4. Woodward's rules - Wikipedia

    en.wikipedia.org/wiki/Woodward's_rules

    With the aid of these rules the UV absorption maximum can be predicted, for example in these two compounds: [8] In the compound on the left, the base value is 214 nm (a heteroannular diene). This diene group has 4 alkyl substituents (labeled 1,2,3,4) and the double bond in one ring is exocyclic to the other (adding 5 nm for an exocyclic double ...

  5. Isosbestic point - Wikipedia

    en.wikipedia.org/wiki/Isosbestic_point

    When an isosbestic plot is constructed by the superposition of the absorption spectra of two species (whether by using molar absorptivity for the representation, or by using absorbance and keeping the same molar concentration for both species), the isosbestic point corresponds to a wavelength at which these spectra cross each other.

  6. Deuterium arc lamp - Wikipedia

    en.wikipedia.org/wiki/Deuterium_arc_lamp

    This is similar to the situation in a hydrogen flame. Arc lamps made with ordinary light-hydrogen provide a very similar UV spectrum to deuterium, and have been used in UV spectroscopes. However, lamps using deuterium have a longer life span and an emissivity (intensity) at the far end of their UV range which is three to five times that of an ...

  7. Electron phenomenological spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Electron_phenomenological...

    For example, EPS is based on the regularities of the correlation of physico-chemical properties and integral spectral characteristics for UV or (and) visible regions of the electromagnetic spectrum (so-called law spectrum-properties). Color is also an integral characteristic of a visible spectrum.

  8. Ultraviolet–visible spectroscopy of stereoisomers - Wikipedia

    en.wikipedia.org/wiki/Ultraviolet–visible...

    Ultraviolet–visible spectroscopy (UV–vis) can distinguish between enantiomers by showing a distinct Cotton effect for each isomer. UV–vis spectroscopy sees only chromophores , so other molecules must be prepared for analysis by chemical addition of a chromophore such as anthracene .

  9. UV detectors - Wikipedia

    en.wikipedia.org/wiki/UV_detectors

    The vast majority of liquid chromatographic systems are equipped with ultraviolet (UV) absorption detectors. The most common UV-Vis detectors used are variable wavelength detectors (VWD), photo diode array detectors (PDA), and diode array detectors (DAD). [4] Variable wavelength detectors decide in advance which wavelength is needed for the ...