enow.com Web Search

  1. Ad

    related to: load charts for lvl beams for construction

Search results

  1. Results from the WOW.Com Content Network
  2. Laminated veneer lumber - Wikipedia

    en.wikipedia.org/wiki/Laminated_veneer_lumber

    LVL is a type of structural composite lumber, comparable to glued laminated timber (glulam) but with a higher allowable stress. [1] A high performance more sustainable alternative to lumber, Laminated Veneer Lumber (LVL) beams, headers and columns are used in structural applications to carry heavy loads with minimum weight. [2]

  3. Flitch beam - Wikipedia

    en.wikipedia.org/wiki/Flitch_beam

    A flitch beam (or flitched beam) is a compound beam used in the construction of houses, decks, and other primarily wood-frame structures. Typically, the flitch beam is made up of a vertical steel plate sandwiched between two wood beams, the three layers being held together with bolts. In that common form it is sometimes referenced as a steel ...

  4. I-joist - Wikipedia

    en.wikipedia.org/wiki/I-joist

    A similar situation occurs where the I-joist crosses a main beam. Installing squash blocks (2×4 materials 1 ⁄ 16 in or 1.6 mm higher than the I-joist) alongside the I-joists transfers the load from the I-joist onto the beam. Missed nails and glue setting too fast can lead to an uneven or squeaky floor.

  5. Parallel-strand lumber - Wikipedia

    en.wikipedia.org/wiki/Parallel-strand_lumber

    The beams are continuously formed, so the length of the beam is limited only to the maximum length that can be handled and transported. Typical widths are 3 + 1 ⁄ 2, 5 + 1 ⁄ 4 or 7 inches (89, 133 or 178 mm); typical depths are 9 + 1 ⁄ 2, 11 + 7 ⁄ 8, 14, 16 and 18 inches (240, 300, 360, 410 and 460 mm). Typically the beams are made to a ...

  6. I-beam - Wikipedia

    en.wikipedia.org/wiki/I-beam

    Tables are available to allow easy selection of a suitable steel I-beam size for a given applied load. I-beams may be used both as beams and as columns. I-beams may be used both on their own, or acting compositely with another material, typically concrete. Design may be governed by any of the following criteria:

  7. Beam (structure) - Wikipedia

    en.wikipedia.org/wiki/Beam_(structure)

    A beam is a structural element that primarily resists loads applied laterally across the beam's axis (an element designed to carry a load pushing parallel to its axis would be a strut or column). Its mode of deflection is primarily by bending , as loads produce reaction forces at the beam's support points and internal bending moments , shear ...

  8. Shear and moment diagram - Wikipedia

    en.wikipedia.org/wiki/Shear_and_moment_diagram

    Shear and Bending moment diagram for a simply supported beam with a concentrated load at mid-span. Shear force and bending moment diagrams are analytical tools used in conjunction with structural analysis to help perform structural design by determining the value of shear forces and bending moments at a given point of a structural element such as a beam.

  9. Lumber - Wikipedia

    en.wikipedia.org/wiki/Lumber

    The main categories of engineered lumber are: [30] Laminated veneer lumber (LVL) – LVL comes in 1 + 3 ⁄ 4-inch (44 mm) thicknesses with depths such as 9 + 1 ⁄ 2, 11 + 7 ⁄ 8, 14, 16, 18 and 24 inches (240, 300, 360, 410, 460 and 610 mm), and are often doubled or tripled up. They function as beams to provide support over large spans, such ...

  1. Ad

    related to: load charts for lvl beams for construction