DIN 488-6: Reinforcing steel - Part 6: Assessment of conformity (2010) BS EN ISO 15630-1: Steel for the reinforcement and prestressing of concrete. Test methods. Reinforcing bars, wire rod and wire. (2010) BS EN ISO 15630-2: Steel for the reinforcement and prestressing of concrete. Test methods. Welded fabric. (2010)
As of April 2021, Devki Group is mainly involved in the manufacture of building materials, including steel, aluminum and cement. At that time, the group was the largest manufacturer of cement and steel in Kenya. [1] The Group's founder and executive chairman, is the majority shareholder in the companies that comprise the group.
Logo of Eurocode 2 An example of a concrete structure. In the Eurocode series of European standards (EN) related to construction, Eurocode 2: Design of concrete structures (abbreviated EN 1992 or, informally, EC 2) specifies technical rules for the design of concrete, reinforced concrete and prestressed concrete structures, using the limit state design philosophy.
A reinforced concrete column is a structural member designed to carry compressive loads, composed of concrete with an embedded steel frame to provide reinforcement. For design purposes, the columns are separated into two categories: short columns and slender columns.
The engineering study of every reinforced concrete construction, whether it is a building, a bridge, a bearing wall, or another structure, dictates the positioning of steel rebars at specific positions in the volume of concrete (predicted concrete cover of steel reinforcement bars). This cover varies between 10 mm and 100 mm.
The reinforcing steel in the bottom part of the beam, which will be subjected to tensile forces when in service, is placed in tension before the concrete is poured around it. Once the concrete has hardened, the tension on the reinforcing steel is released, placing a built-in compressive force on the concrete.
Concrete and steel reinforcement bars combine to create strong, resilient structures in the following ways: Upon contact with each other, the cement paste and steel rebar form a non-reactive surface film preventing corrosion. Reinforcement bars or beams can be strategically set throughout the concrete to achieve the required support system.
Steel never turns into a liquid below this temperature. Pure Iron ('Steel' with 0% Carbon) starts to melt at 1,492 °C (2,718 °F), and is completely liquid upon reaching 1,539 °C (2,802 °F). Steel with 2.1% Carbon by weight begins melting at 1,130 °C (2,070 °F), and is completely molten upon reaching 1,315 °C (2,399 °F).