Search results
Results from the WOW.Com Content Network
This means that VIPs have about one-fifth the thermal conductivity of conventional insulation, and therefore about five times the thermal resistance per unit thickness. Based on a typical k-value of 0.007 W/(m·K), the R-value of a typical 25-millimetre-thick (1 in) VIP would be 3.5 m 2 ·K/W (20 h·ft 2 ·°F/BTU). To provide the same R-value ...
The effectiveness of bulk insulation is commonly evaluated by its R-value, of which there are two – metric (SI) (with unit K⋅W −1 ⋅m 2) and US customary (with unit °F⋅ft 2 ⋅h/BTU), the former being 0.176 times the latter numerically, or the reciprocal quantity the thermal conductivity or U-value W⋅K −1 ⋅m −2.
Although the concept of U-value (or U-factor) is universal, U-values can be expressed in different units. In most countries, U-value is expressed in SI units, as watts per square metre-kelvin: W/(m 2 ⋅K) In the United States, U-value is expressed as British thermal units (Btu) per hour-square feet-degrees Fahrenheit: Btu/(h⋅ft 2 ⋅°F)
Architects and engineers call the resulting values either the U-Value or the R-Value of a construction assembly like a wall. Each type of value (R or U) are related as the inverse of each other such that R-Value = 1/U-Value and both are more fully understood through the concept of an overall heat transfer coefficient described in lower section ...
The construction industry makes use of measures such as the R-value (resistance) and the U-value (transmittance or conductance). Although related to the thermal conductivity of a material used in an insulation product or assembly, R- and U-values are measured per unit area, and depend on the specified thickness of the product or assembly. [note 2]
The insulation in the windward and leeward walls is behaving dynamically in the contra-flux mode with U-values of 0.0008 W/(m 2 K) and 0.1 W/(m 2 K) respectively. Since the building has a square footprint the average U-value for the walls is 0.1252 W/m 2 K. For other wind speeds and directions, the U-values will be different.