Search results
Results from the WOW.Com Content Network
Medical oxygen storage tanks at the Royal Women's Hospital, Melbourne, Australia. Oxygen may be used for patients requiring supplemental oxygen via mask. Usually accomplished by a large storage system of liquid oxygen at the hospital which is evaporated into a concentrated oxygen supply, pressures are usually around 345–380 kPa (50.0–55.1 psi), [1] [2] or in the UK and Europe, 4–5 bar ...
The alveolar oxygen partial pressure is lower than the atmospheric O 2 partial pressure for two reasons. Firstly, as the air enters the lungs, it is humidified by the upper airway and thus the partial pressure of water vapour (47 mmHg) reduces the oxygen partial pressure to about 150 mmHg.
Arterial blood carbon dioxide tension. P a CO 2 – Partial pressure of carbon dioxide at sea level in arterial blood is between 35 and 45 mmHg (4.7 and 6.0 kPa). [9] Venous blood carbon dioxide tension. P v CO 2 – Partial pressure of carbon dioxide at sea level in venous blood is between 40 and 50 mmHg (5.33 and 6.67 kPa). [9]
The blood can also be drawn from an arterial catheter. An ABG test measures the blood gas tension values of the arterial partial pressure of oxygen (PaO2), and the arterial partial pressure of carbon dioxide (PaCO2), and the blood's pH. In addition, the arterial oxygen saturation (SaO2) can be determined. Such information is vital when caring ...
Oxygen tension of mixed venous blood: P (A-a) O 2: Alveolar-arterial oxygen tension difference. The term formerly used (A-a D O 2) is discouraged. P (a/A) O 2: Alveolar-arterial tension ratio; P a O 2:P A O 2 The term oxygen exchange index describes this ratio. C (a-v) O 2: Arteriovenous oxygen content difference: S a O 2: Oxygen saturation of ...
The total concentration of carbon dioxide (in the form of bicarbonate ions, dissolved CO 2, and carbamino groups) in arterial blood (i.e. after it has equilibrated with the alveolar air) is about 26 mM (or 58 ml/100 ml), [19] compared to the concentration of oxygen in saturated arterial blood of about 9 mM (or 20 ml/100 ml blood). [15]
Venous blood with an oxygen concentration of 15 mL/100 mL would therefore lead to typical values of the a-vO 2 diff at rest of around 5 mL/100 mL. During intense exercise, however, the a-vO 2 diff can increase to as much as 16 mL/100 mL due to the working muscles extracting far more oxygen from the blood than they do at rest. [citation needed]
A vacutainer blood collection tube is a sterile glass or plastic test tube with a colored rubber stopper creating a vacuum seal inside of the tube, facilitating the drawing of a predetermined volume of liquid. Vacutainer tubes may contain additives designed to stabilize and preserve the specimen prior to analytical testing.