enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Load bank - Wikipedia

    en.wikipedia.org/wiki/Load_bank

    A load bank is a piece of electrical test equipment used to simulate an electrical load, to test an electric power source without connecting it to its normal operating load. [ 1 ] [ 2 ] During testing, adjustment, calibration, or verification procedures, a load bank is connected to the output of a power source, such as an electric generator ...

  3. Proof test - Wikipedia

    en.wikipedia.org/wiki/Proof_test

    A proof test is a form of stress test to demonstrate the fitness of a load-bearing or impact-experiencing structure. An individual proof test may apply only to the unit tested, or to its design in general for mass-produced items. Such a structure is often subjected to loads above those expected in actual use, demonstrating safety and design margin.

  4. Load rejection - Wikipedia

    en.wikipedia.org/wiki/Load_rejection

    Load rejection in an electric power system is the condition in which there is a sudden load loss in the system which causes the generating equipment to be over-frequency.. A load rejection test is part of commissioning for power systems to confirm that the system can withstand a sudden loss of load and return to normal operating conditions using its governor. [1]

  5. Static load testing - Wikipedia

    en.wikipedia.org/wiki/Static_load_testing

    Static load testing is an in situ type of load testing used in geotechnical investigation to determine the bearing capacity of deep foundations prior to the construction of a building. It differs from the statnamic load test and dynamic load testing in that the pressure applied to the pile is slower.

  6. Load path analysis - Wikipedia

    en.wikipedia.org/wiki/Load_path_analysis

    a): load paths based on U* index; b): von Mises stress distribution [2] In the image to the right, a structural member with a central hole is placed under load bearing stress. Figure (a) shows the U* distribution and the resultant load paths while figure (b) is the von Mises Stress distribution. As can be seen from figure (b), higher stresses ...

  7. Dynamic load testing - Wikipedia

    en.wikipedia.org/wiki/Dynamic_load_testing

    Dynamic load testing (or dynamic loading) is a method to assess a pile's bearing capacity by applying a dynamic load to the pile head (a falling mass) while recording acceleration and strain on the pile head. Dynamic load testing is a high strain dynamic test which can be applied after pile installation for concrete piles. For steel or timber ...

  8. Shaft voltage - Wikipedia

    en.wikipedia.org/wiki/Shaft_voltage

    Insulated bearings eliminate the path to ground through the bearing for current to flow. However, installing insulated bearings does not eliminate the shaft voltage, which will still find the lowest impedance path to ground. This can potentially cause a problem if the path happens to be through the driven load or through some other component.

  9. List of power stations in Ohio - Wikipedia

    en.wikipedia.org/wiki/List_of_power_stations_in_Ohio

    This is a list of electricity-generating power stations in the U.S. state of Ohio, sorted by type and name. In 2022, Ohio had a total summer capacity of 27,447 MW and a net generation of 135,810 GWh. [ 2 ]