enow.com Web Search

  1. Ad

    related to: drainage system sizing chart

Search results

  1. Results from the WOW.Com Content Network
  2. French catheter scale - Wikipedia

    en.wikipedia.org/wiki/French_catheter_scale

    The French size is a measure of the outer diameter of a catheter (not internal drainage channel, or inner diameter). So, for example, if a two-way catheter of 20 Fr is compared to a 20 Fr three-way catheter, they both have the same external diameter but the two-way catheter will have a larger drainage channel than the three-way.

  3. Fixture unit - Wikipedia

    en.wikipedia.org/wiki/Fixture_unit

    In plumbing, a Fixture Unit (FU) or Drain Fixture Unit (DFU) is "a unit of measure, based on the rate of discharge, time of operation and frequency of use of a fixture, that expresses the hydraulic load imposed by that fixture on the sanitary plumbing installation". [1] A Fixture Unit is not a flow rate unit but a design factor.

  4. Plumbing drawing - Wikipedia

    en.wikipedia.org/wiki/Plumbing_drawing

    A plumbing drawing, a type of technical drawing, shows the system of piping for fresh water going into the building and waste going out, both solid and liquid. It also includes fuel gas drawings. Mainly plumbing drawing consist of water supply system drawings, drainage system drawings, irrigation system drawings, storm water system drawings. In ...

  5. Piping and plumbing fitting - Wikipedia

    en.wikipedia.org/wiki/Piping_and_plumbing_fitting

    Underground piping systems for landscaping drainage or the disposal of stormwater or groundwater also use low-pressure gravity flow, so fittings for these systems resemble larger-scale DWV fittings. With high peak-flow volumes, the design and construction of these systems may resemble those of storm sewers .

  6. Chest tube - Wikipedia

    en.wikipedia.org/wiki/Chest_tube

    Portable electronic system Chest tube drainage system diagram, with parts labeled in. A chest drainage system is typically used to collect chest drainage (air, blood, effusions). Most commonly, drainage systems use three chambers which are based on the three-bottle system. The first chamber allows fluid that is drained from the chest to be ...

  7. Pipe (fluid conveyance) - Wikipedia

    en.wikipedia.org/wiki/Pipe_(fluid_conveyance)

    The number system, like Sch 40, 80, 160, were set long ago and seem a little odd. For example, Sch 20 pipe is even thinner than Sch 40, but same OD. And while these pipes are based on old steel pipe sizes, there is other pipe, like cpvc for heated water, that uses pipe sizes, inside and out, based on old copper pipe size standards instead of steel.

  8. Drain-waste-vent system - Wikipedia

    en.wikipedia.org/wiki/Drain-waste-vent_system

    In the U.S., every plumbing fixture must also be coupled to the system's vent piping. [1] Without a vent, negative pressure from water leaving the system can slow flow (resulting in clogs) or cause a siphon to empty a trap. The high point of the vent system (the top of its "soil stack") must be open to the exterior at atmospheric pressure.

  9. Grease trap - Wikipedia

    en.wikipedia.org/wiki/Grease_trap

    Grease trap sizing is based on the size of the 2- or 3-compartment sink, dishwasher, pot sinks, and mop sinks. Many manufacturers and vendors offer online sizing tools to make these calculations easy. The cumulative flow rates of these devices, as well as overall grease retention capacity (in pounds or kilograms) are considered.

  1. Ad

    related to: drainage system sizing chart