enow.com Web Search

  1. Ads

    related to: socomec motorised changeover switch circuit tester model

Search results

  1. Results from the WOW.Com Content Network
  2. Transfer switch - Wikipedia

    en.wikipedia.org/wiki/Transfer_switch

    Simplified single line diagram of a single-phase transfer switch to select either 'city' (utility) power or local generator power 3-phase Intelligent transfer switch. A transfer switch is an electrical switch that switches a load between two sources. Some transfer switches are manual, in that an operator effects the transfer by throwing a ...

  3. Switch - Wikipedia

    en.wikipedia.org/wiki/Switch

    A switch with both types of contact is called a changeover switch or double-throw switch. These may be "make-before-break" ("MBB" or shorting) which momentarily connects both circuits, or may be "break-before-make" ("BBM" or non-shorting) which interrupts one circuit before closing the other.

  4. Chopper (electronics) - Wikipedia

    en.wikipedia.org/wiki/Chopper_(electronics)

    The longer the switch is on compared to the off periods, the higher the total power supplied to the load. The PWM switching frequency has to be much higher than what would affect the load (the device that uses the power), which is to say that the resultant waveform perceived by the load must be as smooth as possible.

  5. High-voltage switchgear - Wikipedia

    en.wikipedia.org/wiki/High-voltage_switchgear

    800 kV high-voltage switchgear. High-voltage switchgear is any switchgear used to connect or disconnect a part of a high-voltage power system.This equipment is essential for the protection and safe operation, without interruption, of a high voltage power system, and is important because it is directly linked to the quality of the electricity supply.

  6. Tap changer - Wikipedia

    en.wikipedia.org/wiki/Tap_changer

    In a typical diverter switch, powerful springs are tensioned by a low power motor (motor drive unit, MDU), and then rapidly released to effect the tap changing operation. To reduce arcing at the contacts, the tap changer operates in a chamber filled with insulating transformer oil, or inside a vessel filled with pressurized SF 6 gas. Reactance ...

  7. Korndörfer autotransformer starter - Wikipedia

    en.wikipedia.org/wiki/Korndörfer_Autotransformer...

    The uncontrolled timing of the changeover allows the peak motor current to be switched at any point on the wave. Figure 5 shows the changeover at 90 degrees. This is a worst-case scenario, peak current at changeover, creates a very high and fast transient. The central switch circuit prevents voltage escalation, as discussed above.

  8. Network analysis (electrical circuits) - Wikipedia

    en.wikipedia.org/wiki/Network_analysis...

    Circuit: A current from one terminal of a generator, through load component(s) and back into the other terminal. A circuit is, in this sense, a one-port network and is a trivial case to analyse. If there is any connection to any other circuits then a non-trivial network has been formed and at least two ports must exist.

  9. Switching control techniques - Wikipedia

    en.wikipedia.org/wiki/Switching_Control_Techniques

    On one hand, intervening on the source is possible by using switching control techniques (increasing the efficiency), redesigning the circuit (costly and time demanding) and using soft switching transition. On the other hand, by adding external or internal filters (also costly) it is possible to address the propagation path. Fig. 1.

  1. Ads

    related to: socomec motorised changeover switch circuit tester model