Search results
Results from the WOW.Com Content Network
Nameplate capacity, also known as the rated capacity, nominal capacity, installed capacity, maximum effect or gross capacity, [1] is the intended full-load sustained output of a facility such as a power station, [2] [3] electric generator, a chemical plant, [4] fuel plant, mine, [5] metal refinery, [6] and many others. Nameplate capacity is the ...
The nominal power of PV devices is measured under standard test conditions (STC), specified in standards such as IEC 61215, IEC 61646 and UL 1703. Specifically, the light intensity is 1000 W/m 2, with a spectrum similar to sunlight hitting the Earth's surface at latitude 35°N in the summer (airmass 1.5), the temperature of the cells being 25 °C.
power rating is specified in terms of apparent power (KVA or MVA), since the exact power factor will be determined by the external factors; [5] power factor (PF) is the nominal power factor for other ratings; usually PF = 0.8; [5] insulation class (B, F, H) for the primary coil. Typical value is F, although older generators might use class B; [5]
Nominal power is the nameplate capacity of photovoltaic (PV) devices, such as solar cells, panels and systems, and is determined by measuring the electric current and voltage in a circuit, while varying the resistance under precisely defined conditions.
A load bank is a piece of electrical test equipment used to simulate an electrical load, to test an electric power source without connecting it to its normal operating load. [ 1 ] [ 2 ] During testing, adjustment, calibration, or verification procedures, a load bank is connected to the output of a power source, such as an electric generator ...
The corners between the sections of the curve define the limits of the power factor (PF) that the generator can sustain at its nameplate capacity (the illustration has the PF ticks placed at 0.85 lagging and 0.95 leading angles).
Nominal power or nameplate capacity is the theoretical output registered with authorities for classifying the unit. For intermittent power sources , such as wind and solar, nameplate power is the source's output under ideal conditions, such as maximum usable wind or high sun on a clear summer day.
The actual production is also influenced by local factors such as dust and ambient temperature, which ideally should be low. As for any power station, the maximum possible power production is the nameplate capacity times the number of hours in a year, while the actual production is the amount of electricity delivered annually to the grid.