enow.com Web Search

  1. Ads

    related to: difference between step up and down transformer in electrical design

Search results

  1. Results from the WOW.Com Content Network
  2. Transformer types - Wikipedia

    en.wikipedia.org/wiki/Transformer_types

    A leakage transformer, also called a stray-field transformer, has a significantly higher leakage inductance than other transformers, sometimes increased by a magnetic bypass or shunt in its core between primary and secondary, which is sometimes adjustable with a set screw. This provides a transformer with an inherent current limitation due to ...

  3. Constant-voltage speaker system - Wikipedia

    en.wikipedia.org/wiki/Constant-voltage_speaker...

    Transformers with various taps allow the installer to adjust the sound pressure level up or down at an individual loudspeaker. Purpose-built models are available that have the transformer contained within the loudspeaker enclosure. The loudspeaker step-down transformer primary is connected in parallel to the constant-voltage line. [3]

  4. Solid-state transformer - Wikipedia

    en.wikipedia.org/wiki/Solid-state_transformer

    This transformer is smaller due to smaller DC-DC inverting stages between transformer coils, which consequently mean smaller transformer coils required to step up or step down voltages. A solid-state transformer can actively regulate voltage and current. Some can convert single-phase power to three-phase power and vice versa.

  5. Electric power distribution - Wikipedia

    en.wikipedia.org/wiki/Electric_power_distribution

    Transformers step down transmission voltages, 35 kV or more, down to primary distribution voltages. These are medium voltage circuits, usually 600–35 000 V. [1] From the transformer, power goes to the busbar that can split the distribution power off in multiple directions. The bus distributes power to distribution lines, which fan out to ...

  6. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    A "delta" (Δ) connected transformer winding is connected between phases of a three-phase system. A "wye" (Y) transformer connects each winding from a phase wire to a common neutral point. A single three-phase transformer can be used, or three single-phase transformers. In an "open delta" or "V" system, only two transformers are used.

  7. Transformer - Wikipedia

    en.wikipedia.org/wiki/Transformer

    In electrical engineering, a transformer is a passive component that transfers electrical energy from one electrical circuit to another circuit, or multiple circuits.A varying current in any coil of the transformer produces a varying magnetic flux in the transformer's core, which induces a varying electromotive force (EMF) across any other coils wound around the same core.

  8. Distribution transformer - Wikipedia

    en.wikipedia.org/wiki/Distribution_transformer

    Distribution transformers typically have ratings less than 200 kVA, [3] although some national standards allow units up to 5000 kVA to be described as distribution transformers. Since distribution transformers are energized 24 hours a day (even when they don't carry any load), reducing iron losses is vital in their design. They usually don't ...

  9. Autotransformer - Wikipedia

    en.wikipedia.org/wiki/Autotransformer

    In practice, losses mean that both standard transformers and autotransformers are not perfectly reversible; one designed for stepping down a voltage will deliver slightly less voltage than required if it is used to step up. The difference is usually slight enough to allow reversal where the actual voltage level is not critical.

  1. Ads

    related to: difference between step up and down transformer in electrical design