enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Lewis lead - Wikipedia

    en.wikipedia.org/wiki/Lewis_lead

    Electrode placement for Lewis lead; RL electrode (green), not shown, remains on leg . A Lewis Lead (also called the S5 lead) is a modified ECG lead used to detect atrial flutter waves when atrial flutter is suspected clinically, based on signs and symptoms, but is not definitely demonstrated on the standard 12 lead ECG.

  3. Electrocardiography - Wikipedia

    en.wikipedia.org/wiki/Electrocardiography

    In a 12-lead ECG, all leads except the limb leads are assumed to be unipolar (aVR, aVL, aVF, V 1, V 2, V 3, V 4, V 5, and V 6). The measurement of a voltage requires two contacts and so, electrically, the unipolar leads are measured from the common lead (negative) and the unipolar lead (positive).

  4. Holter monitor - Wikipedia

    en.wikipedia.org/wiki/Holter_monitor

    Each Holter system has hardware (called monitor or recorder) for recording the signal, and software for review and analysis of the record. There may be a "patient button" on the front that the patient can press at specific instants such as feeling/being sick, going to bed, taking pills, marking an event of symptoms which is then documented in the symptoms diary, etc.; this records a mark that ...

  5. Axillary lines - Wikipedia

    en.wikipedia.org/wiki/Axillary_lines

    The V 5 ECG lead is placed on the anterior axillary line, horizontally even with V 4. The midaxillary line is a coronal line on the torso between the anterior and posterior axillary lines. It is a landmark used in thoracentesis, [2] and the V6 electrode of the 10 electrode ECG.

  6. Einthoven's triangle - Wikipedia

    en.wikipedia.org/wiki/Einthoven's_triangle

    Electrodes may be placed distally or proximally on the limb without affecting the recording. [5] The right leg electrode acts to reduce interference, and can be placed anywhere without an effect on the ECG results. [6] Each lead measures the electric field created by the heart during the depolarization and repolarization of myocytes. The ...

  7. Cardiac resynchronization therapy - Wikipedia

    en.wikipedia.org/wiki/Cardiac_resynchronization...

    The leads are: - Atrial lead at the right appendage - Right ventricular lead at the apex - Left ventricular lead through the coronary sinus. [7] CRT requires the placement of an electrical device for biventricular pacing, along with placement of (at least) two pacing leads, to facilitate stable left ventricular and right ventricular pacing.

  8. Right axis deviation - Wikipedia

    en.wikipedia.org/wiki/Right_axis_deviation

    This refers to the appearance of leads I and II. If the QRS complex is negative in lead I and positive in lead II, the QRS complexes appear to be "reaching" to touch each other. This signifies right axis deviation. Conversely, if the QRS complex is positive in lead I and negative in lead II the leads have the appearance of "leaving" each other.

  9. Electrocardiography in myocardial infarction - Wikipedia

    en.wikipedia.org/wiki/Electrocardiography_in...

    The 2018 European Society of Cardiology/American College of Cardiology Foundation/American Heart Association/World Health Federation Universal Definition of Myocardial Infarction for the ECG diagnosis of the ST segment elevation type of acute myocardial infarction require new ST elevation at J point of at least 1mm (0.1 mV) in two contiguous leads with the cut-points: ≥1 mm in all leads ...