The primary reason for the use of isolated grounds (IG) is to provide a noise-free ground return, separate from the equipment grounding (EG) return. The EG circuit includes all of the metal conduit, outlet boxes, and metal enclosures that contain the wiring and must be grounded to provide a safe return path in case of fault currents.
Per UL Standard ANSI/UL 498, a receptacle (any color) with an orange triangle, is an isolated ground (IG) device, where the grounding pin of the receptacle is connected to ground independently of the frame of the receptacle and wiring outlet box. This is also a requirement of the National Electrical Code (NFPA 70), Article 406.
The ground tab is designed to be attached to the outlet faceplate screw, which is supposed to be connected to the building electrical ground. A cheater plug, AC ground lifter or three-prong/two-prong adapter is an adapter that allows a NEMA 5-15P grounding-type plug (three prongs) to connect to a NEMA 1-15R non-grounding receptacle (two slots).
A ground connection that is missing or of inadequate capacity may not provide the protective functions as intended during a fault in the connected equipment. Extra connections between ground and circuit neutral may result in circulating current in the ground path, stray current introduced in the earth or in a structure, and stray voltage.
An earthing system (UK and IEC) or grounding system (US) connects specific parts of an electric power system with the ground, typically the equipment's conductive surface, for safety and functional purposes. [1] The choice of earthing system can affect the safety and electromagnetic compatibility of the installation.
The ground connection can become oxidized and when the shells are made of metal any ground fault goes right through the hands of a person connecting/disconnecting a male and a female cable connector (unless the person wears insulating gloves). Incorrect use of the ground connector as a neutral was not uncommon.
The ground hole is officially D-shaped, although some round holes exist and many plugs have round ground pins. Both current-carrying blades on grounding plugs may be narrow, since the ground pin enforces polarity, but outlets have a wider opening for the neutral blade to prevent ungrounded polarized plugs from being put in backwards.
For very large currents in generating stations or substations, where it is difficult to provide circuit protection, an isolated-phase bus is used. Each phase of the circuit is run in a separate grounded metal enclosure. The only fault possible is a phase-to-ground fault, since the enclosures are separated.