For comparison, phenolic foam insulation has a k-value of around 0.018 W/(m⋅K), [23] while wood varies anywhere from 0.15 to 0.75 W/(m⋅K), and steel has a k-value of approximately 50.0 W/(m⋅K). These figures vary from product to product, so the UK and EU have established a 90/90 standard which means that 90% of the product will conform to ...
This is a list of insulation materials used around the world. Typical R-values are given for various materials and structures as approximations based on the average of available figures and are sorted by lowest value. R-value at 1 m gives R-values normalised to a 1 metre (3 ft 3 in) thickness and sorts by median value of the range.
Insulated vinyl siding with added fan fold foam board insulation raises the R-value to 3.5 - 7.5. Fan fold insulation is installed under the final siding product. The expanded polystyrene foam (EPS) insulation allows for more impact resistance than traditional vinyl siding. The rigid foam-backed siding creates straighter sight lines, and ...
EPS is the most common of the foams used and has an R-value (thermal resistance) of about 4 °F·ft 2 ·h/Btu (equivalent to about 0.7 K·m 2 /W) per 25 mm thickness, which would give the 3.5 inches (89 mm) of foam in a 4.5-inch-thick (110 mm) panel an R value of 13.8 (caution: extrapolating R-values over thickness may be imprecise due to non ...
Polyurethane is a closed-cell foam insulation material that initially contains a low-conductivity gas in its cells. [6] As a result of the high thermal resistance of the gas, spray polyurethane insulation typically has an initial R-value around R-3.4 to R-6.7 per inch. [6] In comparison, glass wool typically has an R-Value of only R-3 to R-4 ...
This means that VIPs have about one-fifth the thermal conductivity of conventional insulation, and therefore about five times the thermal resistance per unit thickness. Based on a typical k-value of 0.007 W/(m·K), the R-value of a typical 25-millimetre-thick (1 in) VIP would be 3.5 m 2 ·K/W (20 h·ft 2 ·°F/BTU). To provide the same R-value ...
The thermal resistance of a material depends on thickness. Presumably for ease of comparison, the resistance given for each material is for a one inch thick slice. The material is one inch thick irrespective of the system of units used to convey its resistance.
The thermal resistance R-value provided by Thinsulate products varies by the specific thickness and construction of the fabric. [12] Values (US units) range from 1.6 for 80-gram fabric to 2.9 for 200-gram fabric. [13] Thinsulate is considered "the warmest thin apparel insulation" available.