Biventricular pacemaker. This pacemaker has three wires placed in three chambers of the heart. One in the atrium and two in either ventricle. It is more complicated to implant. [10] Rate-responsive pacemaker. This pacemaker has sensors that detect changes in the patient's physical activity and automatically adjust the pacing rate to fulfill the ...
Cardiac resynchronisation therapy (CRT or CRT-P) is the insertion of electrodes in the left and right ventricles of the heart, as well as on occasion the right atrium, to treat heart failure by coordinating the function of the left and right ventricles via a pacemaker, a small device inserted into the anterior chest wall.
All three presentations allow distinct and easily reproducible electrical signatures as illustrated by left and right bundle branch blocks, hemiblocks, etc. The concise measurement of the time and morphology of the QRS interval allows the interventional ability to manipulate this interval with biventricular pacemakers.
An artificial cardiac pacemaker (or artificial pacemaker, so as not to be confused with the natural cardiac pacemaker) or just pacemaker is an implanted medical device that generates electrical impulses delivered by electrodes to the chambers of the heart either the upper atria, or lower ventricles to cause the targeted chambers to contract and ...
The biological pacemaker is intended as an alternative to the artificial cardiac pacemaker that has been in human use since the late 1950s. Despite their success, several limitations and problems with artificial pacemakers have emerged during the past decades such as electrode fracture or damage to insulation , infection , re-operations for ...
Since pacemaker correction of the third-degree block requires full-time pacing of the ventricles, a potential side effect is pacemaker syndrome, and may necessitate the use of a biventricular pacemaker, which has an additional 3rd lead placed in a vein in the left ventricle, providing more coordinated pacing of both ventricles. [citation needed]
Just like pacemakers, ICDs can have a single wire or lead in the heart (in the right ventricle, single chamber ICD), two leads (in the right atrium and right ventricle, dual chamber ICD) or three leads (biventricular ICD, one in the right atrium, one in the right ventricle and one on the outer wall of the left ventricle).
Crosstalk can only occur in a dual chamber or biventricular pacemaker. It happens less often in more recent models of dual chamber pacemakers due to the addition of a ventricular blanking period, which coincides with the atrial stimulus. This helps to prevent ventricular channel oversensing of atrial output.