Ads
related to: digital swr power meterebay.com has been visited by 1M+ users in the past month
Search results
Results from the WOW.Com Content Network
An SWR meter does not measure the actual impedance of a load (the resistance and reactance), but only the mismatch ratio. To measure the actual impedance requires an antenna analyzer or other similar RF measuring device. For accurate readings, the SWR meter itself must also match the line's impedance (typically 50 or 75 Ohms).
The SWR meter requires a transmitter or signal generator to provide a few watts power test signal. An antenna bridge is able to measure at low power, but also requires a supplied test signal; depending on the bridge circuit, it can be used to measure both reactance and resistance by reading values marked on knobs that have been adjusted for a ...
The power standing wave ratio (PSWR) is defined as the square of the VSWR, [3] however, this deprecated term has no direct physical relation to power actually involved in transmission. SWR is usually measured using a dedicated instrument called an SWR meter.
Commonly an SWR meter and/or directional wattmeter are used to check the extent of the match between the aerial system and the transmitter via the transmission line (feeder). A directional wattmeter indicates forward power, reflected power, and often SWR as well.
A high SWR indicates a poor match between the feed line and the antenna, which increases wasted power, can cause damage to components in the transmission path, possibly including the transmitter, and cause distortion to TV, FM stereo and digital signals. With the input power set so that the maxima are at 0 dBm, a measurement of a minimum in ...
To adjust the matching network the simplest instrument to measure the degree of mismatch between the feedline and the antenna is called an SWR meter (standing wave ratio meter), which reports the standing wave ratio (SWR) on the line: The ratio of the adjacent maximum and minimum voltage or current on the line. A ratio of 1:1 indicates an ...
When measuring with a field strength meter it is important to use a calibrated antenna such as the standard antenna supplied with the meter. For precision measurements the antenna must be at a standard height. A value of standard height frequently employed for VHF and UHF measurements is 10 metres (33 ft).
Capacitance meter: Measures the capacitance component Current clamp: Measures current without physical connection Curve tracer: Applies swept signals to a device and allows display of the response Cos Phi Meter: Measures the power factor Distortionmeter: Measures the distortion added to a circuit Electricity meter: Measures the amount of energy ...
Ads
related to: digital swr power meterebay.com has been visited by 1M+ users in the past month