Search results
Results from the WOW.Com Content Network
The gauge is then removed and measured with the aid of a micrometer anvil heads, move the head of the gauge around while making the measurement to ensure you get the maximum reading. Grasp the gauge near the head to aid in your maneuvering of the gauge while adjusting the micrometer so it just stops the gauge's motion at one spot only.
The technicians who work in the PMEL will often specialize in one of these sections. The K-Sections are derived from the primary function of the TMDE. This is based upon the calibration authority. Most labs have three calibration sections divided into K1/K8, K5/K6 and K3/K4 that specialize in like test equipment.
Lock nut, lock-ring, or thimble lock: The knurled component (or lever) that one can tighten to hold the spindle stationary, such as when momentarily holding a measurement. Thimble: The component that one's thumb turns. Screw: (Not visible) The heart of the micrometer, as explained under "Operating principles". It is inside the barrel.
On a manual milling machine, the micrometer adjustment nut limits the depth to which the cutting tool may plunge into the workpiece. The nut is located on a threaded rod on the mill head. The machine operator moves it up or down by rotating it clockwise (to move it down) or counter-clockwise (to move it up).
The pictured accessories provide a set of holders and tools to extend the usefulness of the gauge block set. They provide a means of securely clamping large stacks together, along with reference points, scribers, and various shapes of blocks that act like caliper jaws, either external or internal. Conical-tip ones ease measurement of center-to ...
The formal definition of calibration by the International Bureau of Weights and Measures (BIPM) is the following: "Operation that, under specified conditions, in a first step, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties (of the calibrated instrument or ...
MSA analyzes the collection of equipment, operations, procedures, software and personnel that affects the assignment of a number to a measurement characteristic. A measurement system analysis considers the following: Selecting the correct measurement and approach; Assessing the measuring device; Assessing procedures and operators
A go/no-go gauge is an inspection tool used to check a workpiece against its allowed tolerances via a go/no-go test. Its name is derived from two tests: the check involves the workpiece having to pass one test (go) and fail the other (no-go). For example, ISO 1502 sets a standard for screw threads and gauging to test them.