enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Air gap (plumbing) - Wikipedia

    en.wikipedia.org/wiki/Air_gap_(plumbing)

    Water cannot flow from the sink to the tap in normal circumstances, even if the water supply loses pressure. An air gap , as related to the plumbing trade, is the unobstructed vertical space between the water outlet and the flood level of a fixture . [ 1 ]

  3. Plumbing fixture - Wikipedia

    en.wikipedia.org/wiki/Plumbing_fixture

    Each fixture usually has a characteristic means of connection. Normal plumbing practice is to install a valve on each water supply line before the fixture, and this is most commonly termed a stop or "service valve". The water supply to some fixtures is cold water only (such as water closets and urinals). Most fixtures also have a hot water supply.

  4. Thermal expansion valve - Wikipedia

    en.wikipedia.org/wiki/Thermal_expansion_valve

    A thermal expansion valve or thermostatic expansion valve (often abbreviated as TEV, TXV, or TX valve) is a component in vapor-compression refrigeration and air conditioning systems that controls the amount of refrigerant released into the evaporator and is intended to regulate the superheat of the refrigerant that flows out of the evaporator ...

  5. File:Diagram of a Refrigerator Door from 1912.pdf - Wikipedia

    en.wikipedia.org/wiki/File:Diagram_of_a...

    to share – to copy, distribute and transmit the work; to remix – to adapt the work; Under the following conditions: attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.

  6. Isolation valve - Wikipedia

    en.wikipedia.org/wiki/Isolation_valve

    These valves are normally left open so that the user can control the flow of water with the spigot above the sink, and does not need to reach under the counter to start or stop the water flow. However, if the spigot needs to be replaced (i.e. maintenance needs to take place on the system), the isolation valves are shut to stop the flow of water ...

  7. Reduced pressure zone device - Wikipedia

    en.wikipedia.org/wiki/Reduced_pressure_zone_device

    A reduced pressure zone device (RPZD, RPZ, or RPZ valve) is a type of backflow prevention device used to protect water supplies from contamination. RPZDs may also be known as reduced pressure principle (RP), reduced pressure principle backflow prevention devices , [ 1 ] [ 2 ] reduced pressure zone assemblies (RPZA), [ 3 ] or reduced pressure ...

  8. Heat pump and refrigeration cycle - Wikipedia

    en.wikipedia.org/wiki/Heat_pump_and...

    Thermodynamic heat pump cycles or refrigeration cycles are the conceptual and mathematical models for heat pump, air conditioning and refrigeration systems. [1] A heat pump is a mechanical system that transmits heat from one location (the "source") at a certain temperature to another location (the "sink" or "heat sink") at a higher temperature. [2]

  9. Ballcock - Wikipedia

    en.wikipedia.org/wiki/Ballcock

    As the tank water level drops, the float descends and actuates the fill valve. Water is fed to the tank to replenish its supply, and a smaller flow is directed into the overflow tube to refill the bowl. Once the flapper valve closes, the water flow from the fill valve continues until the tank level again reaches the fill line.