The most common three-phase system will have three hot legs, 208 V to each other and 120 V each to the neutral. An older, but still widely used, high-leg delta system uses three phases with 240 volts phase-to-phase for motor loads, and 120 volts for lighting loads by use of a center-tapped transformer; two of the phases are 120 volts to neutral ...
United States: A B NEMA 14-30 NEMA 14-50 NEMA 1-15 NEMA 5-15 NEMA 14-30 NEMA 14-50 120 V 120 V 240 V 240 V 120/208 V 277/480 V 120/240 V 240 V 480 V 60 Hz NEMA 5-20R outlets, which are similar to type B but have a T-shaped neutral slot, are sometimes used for higher current 120 V equipment (up to 20 A). U.S. Virgin Islands: A B NEMA 1-15P
The United States and Canada use a supply voltage of 120 volts ± 6%. Japan, Taiwan, Saudi Arabia, North America, Central America and some parts of northern South America use a voltage between 100 V and 127 V. However, most of the households in Japan equip split-phase electric power like the United States, which can supply 200 V by using ...
So if A–B, B–C and C–A are all 240 volts, then A–N and C–N will both be 120 volts, but B–N will be 208 volts. Other types of three-phase supplies are wye connections, ungrounded delta connections, or corner-grounded delta [2] (ghost leg configuration) connections. These connections do not supply split single-phase power, and do not ...
The addition is a 3 ⁄ 16-inch (4.8 mm) diameter round or U-shaped ground pin, 1 ⁄ 8 in (3.2 mm) longer than the power blades (so the device is grounded before the power is connected) and located from them by 1 ⁄ 4 in (6.4 mm) edge-to-edge or 15 ⁄ 32 in (11.9 mm) center-to-center.
Single-pole circuit breakers feed 120 V circuits from one of the 120 V buses within the panel, or two-pole circuit breakers feed 240-volt circuits from both buses. 120 V circuits are the most common, and used to power NEMA 1 and NEMA 5 outlets, and most residential and light commercial direct-wired lighting circuits.
Inductive and capacitive loads will cause current to either lag or lead the voltage. However, the relative phase angle between each pair of lines (1 to 2, 2 to 3, and 3 to 1) will still be −120°. A phasor diagram for a wye configuration, in which V ab represents a line voltage, and V an represents a phase voltage. Voltages are balanced as
Most of the Americas use 60 Hz AC, the 120/240 volt split-phase system domestically and three phase for larger installations. North American transformers usually power homes at 240 volts, similar to Europe's 230 volts. It is the split-phase that allows use of 120 volts in the home. Japan's utility frequencies are 50 Hz and 60 Hz.