Search results
Results from the WOW.Com Content Network
The transient hot wire method has advantage over the other thermal conductivity methods, since there is a fully developed theory and there is no calibration or single-point calibration. Furthermore, because of the very small measuring time (1 s) there is no convection present in the measurements and only the thermal conductivity of the fluid is ...
The transient hot wire method has advantage over the other thermal conductivity method since there is a fully developed theory and there is no calibration or single-point calibration. Furthermore, because of the very small measuring time (1 s) there is no convection present in the measurements and only the thermal conductivity of the fluid is ...
J. H. Neher and M. H. McGrath were two electrical engineers who wrote a paper in 1957 about how to calculate the capacity of current (ampacity) of cables. [1] The paper described two-dimensional highly symmetric simplified calculations which have formed the basis for many cable application guidelines and regulations.
is the thermal conductivity (W/(K·m)) of the sample; is the thermal resistivity (K·m/W) of the sample; is the cross-sectional area (m 2) perpendicular to the path of heat flow. In terms of the temperature gradient across the sample and heat flux through the sample, the relationship is:
Additional research in Thermal radiation and appliance heat gain with respect to CLTD data was also completed shortly after the original publication of the method. The advancements in each of these areas inspired a revision/compilation effort, and in 1993 the CLTD/CLF/SCL method was succinctly compiled by Spitler, McQuiston, and Lindsey. [1]
In soldering, a thermal profile is a complex set of time-temperature values for a variety of process dimensions such as slope, soak, TAL, and peak. [8] Solder paste contains a mix of metal, flux, and solvents that aid in the phase change of the paste from semi-solid, to liquid to vapor; and the metal from solid to liquid.
A variant of the metric perm is used in DIN Standard 53122, where permeance is also expressed in grams per square meter per day, but at a fixed, "standard" vapor-pressure difference of 17.918 mmHg. This unit is thus 17.918 times smaller than a metric perm, corresponding to about 0.084683 of a U.S. perm.
The plate distance is one centimeter, the special conductivity values were calculated from the Lasance approximation formula in The Thermal conductivity of Air at Reduced Pressures and Length Scales [28] and the primary values were taken from Weast at the normal pressure tables in the CRC handbook on page E2.