enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Evans balance - Wikipedia

    en.wikipedia.org/wiki/Evans_balance

    An Evans balance, also known as a Johnson Matthey magnetic susceptibility balance, is a scientific instrument used to measure the magnetic susceptibility of solids and liquids. [ 1 ] [ 2 ] Magnetic susceptibility quantifies the extent to which a material becomes magnetized in an applied magnetic field .

  3. Gouy balance - Wikipedia

    en.wikipedia.org/wiki/Gouy_balance

    Schematic diagram of Gouy balance. The Gouy balance, invented by the French physicist Louis Georges Gouy, is a device for measuring the magnetic susceptibility of a sample. . The Gouy balance operates on magnetic torque, by placing the sample on a horizontal arm or beam suspended by a thin fiber, and placing either a permanent magnet or electromagnet on the other end of the arm, there is a ...

  4. Internal standard - Wikipedia

    en.wikipedia.org/wiki/Internal_standard

    The calibration curve that does not use the internal standard method ignores the uncertainty between measurements. The coefficient of determination (R 2) for this plot is 0.9985. In the calibration curve that uses the internal standard, the y-axis is the ratio of the nickel signal to the yttrium signal.

  5. CRC Handbook of Chemistry and Physics - Wikipedia

    en.wikipedia.org/wiki/CRC_Handbook_of_Chemistry...

    The CRC Handbook of Chemistry and Physics is a comprehensive one-volume reference resource for science research. First published in 1914, it is currently (as of 2024 [update] ) in its 105th edition, published in 2024.

  6. Calibration curve - Wikipedia

    en.wikipedia.org/wiki/Calibration_curve

    A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]

  7. Hall effect sensor - Wikipedia

    en.wikipedia.org/wiki/Hall_effect_sensor

    Hall effect magnetometers (also called tesla meters or gauss meters) use a Hall probe [23] with a Hall element to measure magnetic fields or inspect materials (such as tubing or pipelines) using the principles of magnetic flux leakage. A Hall probe is a device that uses a calibrated Hall effect sensor to directly measure the strength of a ...

  8. Ball-pen probe - Wikipedia

    en.wikipedia.org/wiki/Ball-pen_probe

    where is measured by the ball-pen probe, by the standard Langmuir probe, and is given by the Langmuir probe geometry, plasma gas composition, the magnetic field, and other minor factors (secondary electron emission, sheath expansion, etc.). It can be calculated theoretically, its value being about 3 for a non-magnetized hydrogen plasma.

  9. Leeb rebound hardness test - Wikipedia

    en.wikipedia.org/wiki/Leeb_rebound_hardness_test

    The quotient 1000×v r /v i is quoted in the Leeb rebound hardness unit HLx (where x indicates the probe and impact body type: D, DC, DL, C, G, S, E) . [ 1 ] [ 3 ] While in the traditional static tests the test force is applied uniformly with increasing magnitude, dynamic testing methods apply an instantaneous load.