enow.com Web Search

  1. Ads

    related to: 6 3 wire amp rating

Search results

  1. Results from the WOW.Com Content Network
  2. American wire gauge - Wikipedia

    en.wikipedia.org/wiki/American_wire_gauge

    American Wire Gauge (AWG) is a logarithmic stepped standardized wire gauge system used since 1857, predominantly in North America, for the diameters of round, solid, nonferrous, electrically conducting wire. Dimensions of the wires are given in ASTM standard B 258. [1] The cross-sectional area of each gauge is an important factor for ...

  3. Ampacity - Wikipedia

    en.wikipedia.org/wiki/Ampacity

    A lower rating will apply if multiple conductors are in proximity, since each contributes heat to the others and diminishes the amount of external cooling of the conductors. Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75, and 90 °C, often with an ambient air ...

  4. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    All NEMA 6 devices are three-wire grounding devices (hot-hot-ground) used for 208 and 240 V circuits and rated for 250 V maximum, with the 6-15, 6-20 and 6-30 being grounding versions of the 2-15, 2-20 and 2-30, respectively. The 6-15 resembles the 5-15, but with collinear horizontal pins, spaced 23 ⁄ 32 in (18.3 mm) center-to-center. The 20 ...

  5. NEMA enclosure types - Wikipedia

    en.wikipedia.org/wiki/NEMA_enclosure_types

    Each type specifies characteristics of an enclosure, but not, for example, a specific enclosure size. Note that higher numbers do not include the lower-numbered tests. For example, types 3, 4 and 6 are intended for outdoor use, but type 5 is not. A NEMA enclosure rating does not mean that it also meets the same UL enclosure rating.

  6. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    In both those instances the white wire should be identified as being hot, usually with black tape inside junction boxes. The neutral wire is identified by gray or white insulated wire, perhaps using stripes or markings. With lamp cord wire the ribbed wire is the neutral, and the smooth wire is the hot. NEC 2008 400.22(f) allows surface marking ...

  7. IEC 60309 - Wikipedia

    en.wikipedia.org/wiki/IEC_60309

    The standard includes preferred current ratings and wire gauges for both International (deemed Series I) and North American (deemed Series II) applications. Series I preferred current ratings (in amps) are: 16, 32, 63, 125, 250, 400, 630 and 800, with wire gauges specified as mm 2 .

  1. Ads

    related to: 6 3 wire amp rating