A fault current limiter (FCL), also known as fault current controller (FCC), [1] is a device which limits the prospective fault current when a fault occurs (e.g. in a power transmission network) without complete disconnection. The term includes superconducting, solid-state and inductive devices. [2]
Current limiting reactors, once called current limiting reactance coils, were first presented in 1915. [2] The inventor of the current limiting reactance coil was Vern E. Alden who filed the patent on November 20, 1917 with an issue date of September 11, 1923. The original assignee was Westinghouse Electric & Manufacturing Company. [3]
An inrush current limiter is a device or devices combination used to limit inrush current. Passive resistive components such as resistors (with power dissipation drawback), or negative temperature coefficient (NTC) thermistors are simple options while the positive one (PTC) is used to limit max current afterward as the circuit has been operating (with cool-down time drawback on both).
Due to the fast recharge times and fast alternating current to direct current conversion process of SMES systems, these systems can be used as a spinning reserve when a major grid of transmission line is out of service. [18] [19] SFCL. Superconducting fault current limiters (SFCL) are used to limit current under a fault in the grid.
Category for standard protection devices fitted to commercial or domestic electrical supplies, to monitor leakages to earth, which cause a subsequent over-current Pages in category "Over-current protection devices"
Each sectionalizer detects and counts fault current interruptions by the recloser (or circuit breaker). After a pre-determined number of interruptions, the sectionalizer will open, thereby isolating the faulty section of the circuit, allowing the recloser to restore supply to the other non-fault sections. [ 18 ]
Early applications will be where the benefit of smaller size, lower weight or the ability to rapidly switch current (fault current limiters) outweighs the added cost. Longer-term as conductor price falls HTS systems should be competitive in a much wider range of applications on energy efficiency grounds alone.
A resistance earth system is used for mining in India as per Central Electricity Authority Regulations. Instead of a solid connection of neutral to earth, a neutral grounding resistor (NGR) is used to limit the current to ground to less than 750 mA. Due to the fault current restriction it is safer for gassy mines. [16]