Search results
Results from the WOW.Com Content Network
Peak-to-peak amplitude (abbreviated p–p or PtP or PtoP) is the change between peak (highest amplitude value) and trough (lowest amplitude value, which can be negative). With appropriate circuitry, peak-to-peak amplitudes of electric oscillations can be measured by meters or by viewing the waveform on an oscilloscope .
Here the coefficient A is the amplitude, x 0, y 0 is the center, and σ x, σ y are the x and y spreads of the blob. The figure on the right was created using A = 1, x 0 = 0, y 0 = 0, σ x = σ y = 1.
The complex constant, which depends on amplitude and phase, is known as a phasor, or complex amplitude, [4] [5] and (in older texts) sinor [6] or even complexor. [ 6 ] A common application is in the steady-state analysis of an electrical network powered by time varying current where all signals are assumed to be sinusoidal with a common frequency.
When two signals with these waveforms, same period, and opposite phases are added together, the sum + is either identically zero, or is a sinusoidal signal with the same period and phase, whose amplitude is the difference of the original amplitudes. The phase shift of the co-sine function relative to the sine function is +90°.
The two amplitude-modulated sinusoids are known as the in-phase (I) and quadrature (Q) components, which describes their relationships with the amplitude- and phase-modulated carrier. [ A ] [ 2 ] Or in other words, it is possible to create an arbitrarily phase-shifted sine wave, by mixing together two sine waves that are 90° out of phase in ...
Assuming a full-scale sine wave signal (that is, the quantizer is designed such that it has the same minimum and maximum values as the input signal), the quantization noise approximates a sawtooth wave with peak-to-peak amplitude of one quantization level [11] and uniform distribution. In this case, the SNR is approximately
The logarithmic decrement can be obtained e.g. as ln(x 1 /x 3).Logarithmic decrement, , is used to find the damping ratio of an underdamped system in the time domain.. The method of logarithmic decrement becomes less and less precise as the damping ratio increases past about 0.5; it does not apply at all for a damping ratio greater than 1.0 because the system is overdamped.
The most common test signals that fulfill this are full amplitude triangle waves and sawtooth waves. For example, a 16-bit ADC has a maximum signal-to-quantization-noise ratio of 6.02 × 16 = 96.3 dB. When the input signal is a full-amplitude sine wave the distribution of the signal is no longer uniform, and the corresponding equation is instead