enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Duct leakage testing - Wikipedia

    en.wikipedia.org/wiki/Duct_leakage_testing

    Duct leakage test in the US. A duct leakage tester is a diagnostic tool designed to measure the airtightness of forced air heating, ventilating and air-conditioning (HVAC) ductwork. A duct leakage tester consists of a calibrated fan for measuring an air flow rate and a pressure sensing device to measure the pressure created by the fan flow.

  3. Air Movement and Control Association - Wikipedia

    en.wikipedia.org/wiki/Air_Movement_and_Control...

    ANSI/AMCA Standard 510 - Methods of Testing Heavy Duty Dampers for Rating establishes testing methods to be used in measuring the performance of dampers generally described as “custom design,” “heavy duty” or “severe service” normally used in applications where elevated temperature, erosion and/or corrosion conditions exist ...

  4. Blower door - Wikipedia

    en.wikipedia.org/wiki/Blower_door

    Duct leakage testing of forced air heating/cooling systems - both supply (vents) ducts and return ducts can be tested to determine if and how much they leak air. A duct test can be combined with a blower door test to measure the total leakage to outside, measuring effective leakage to the outside of the house only.

  5. Testing, adjusting, balancing - Wikipedia

    en.wikipedia.org/wiki/Testing,_adjusting,_balancing

    In heating, ventilation, and air conditioning (HVAC), testing, adjusting and balancing (TAB) are the three major steps used to achieve proper operation of heating, ventilation, and air conditioning systems. TAB usually refers to commercial building construction and the specialized contractors who employ personnel that perform this service.

  6. Ductwork airtightness - Wikipedia

    en.wikipedia.org/wiki/Ductwork_airtightness

    The relationship between pressure and leakage air flow rate is defined by the power law model between the airflow rate and the pressure difference across the ductwork envelope as follows: q L =C L ∆p n. where: q L is the volumetric leakage airflow rate expressed in L.s −1; C L is the air leakage coefficient expressed in L.s −1.Pa −n

  7. Air Conditioning, Heating and Refrigeration Institute - Wikipedia

    en.wikipedia.org/wiki/Air_Conditioning,_Heating...

    Logo. The Air Conditioning, Heating, and Refrigeration Institute (AHRI), formed in 2008 by a merger of the Air-Conditioning and Refrigeration Institute (ARI) and the Gas Appliance Manufacturers Association (GAMA), is a North American trade association of manufacturers of air conditioning, heating, and commercial refrigeration equipment.

  8. Passive house - Wikipedia

    en.wikipedia.org/wiki/Passive_house

    In order to achieve these metrics, best practice is to test the building air barrier enclosure with a blower door at mid-construction if possible. [ 2 ] [ 61 ] A passive house is designed so that most of the air exchange with exterior is done by controlled ventilation through a heat-exchanger in order to minimize heat loss (or gain, depending ...

  9. Infiltration (HVAC) - Wikipedia

    en.wikipedia.org/wiki/Infiltration_(HVAC)

    Infiltration is sometimes called air leakage. The leakage of room air out of a building, intentionally or not, is called exfiltration . Infiltration is caused by wind , negative pressurization of the building, and by air buoyancy forces known commonly as the stack effect .