enow.com Web Search

  1. Ads

    related to: high velocity duct system

Search results

  1. Results from the WOW.Com Content Network
  2. Sound attenuator - Wikipedia

    en.wikipedia.org/wiki/Sound_attenuator

    While flow conditions in typical low velocity duct systems rarely exceed 2000–3000 ft/min, sound attenuators for steam vents must withstand airflow velocities in the 15,000-20,000 ft/min. range. [10] The acoustic performance of a sound attenuator is tested over a range of airflow velocities, and for forward and reverse flow conditions.

  3. Room air distribution - Wikipedia

    en.wikipedia.org/wiki/Room_air_distribution

    Displacement ventilation systems supply air directly to the occupied zone.The air is supplied at low velocities to cause minimal induction and mixing. This system is used for ventilation and cooling of large high spaces, such as auditorium and atria, where energy may be saved if only the occupied zone is treated rather than trying to control the conditions in the entire space.

  4. Displacement ventilation - Wikipedia

    en.wikipedia.org/wiki/Displacement_ventilation

    Displacement ventilation systems are quieter than conventional overhead systems with better ventilation efficiency. Hence, it could enhance indoor air quality and provide desirable acoustic environment. Displacement ventilation systems are appropriate in space where high ventilation is required, such as classrooms, conference rooms, and offices.

  5. Heating, ventilation, and air conditioning - Wikipedia

    en.wikipedia.org/wiki/Heating,_ventilation,_and...

    Warm air systems distribute the heated air through ductwork systems of supply and return air through metal or fiberglass ducts. Many systems use the same ducts to distribute air cooled by an evaporator coil for air conditioning. The air supply is normally filtered through air filters [dubious – discuss] to remove dust and pollen particles. [15]

  6. Register (air and heating) - Wikipedia

    en.wikipedia.org/wiki/Register_(air_and_heating)

    The velocity of air through a register is usually kept low enough so that it is masked by background noise. (Higher ambient levels of background noise, such as those in restaurants, allow higher air velocities.) On the other hand, air velocity must be high enough to achieve the desired temperature. [6] Registers are a critical part of the HVAC ...

  7. Process duct work - Wikipedia

    en.wikipedia.org/wiki/Process_Duct_Work

    Note: the duct gas velocity is chosen to minimize duct dust dropout. Cement and lime plant duct velocity at normal operations is 3000 to 3200 foot per minute, lead plant velocities are 4000 to 4500 foot per minute, as the dust is heavier. Other industries, such as grain have lower gas velocities.

  1. Ads

    related to: high velocity duct system