enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Pulmonary function testing - Wikipedia

    en.wikipedia.org/wiki/Pulmonary_function_testing

    Pulmonary function testing is a safe procedure; however, there is cause for concern regarding untoward reactions and the value of the test data should be weighed against potential hazards. Some complications include dizziness, shortness of breath, coughing, pneumothorax, and inducing an asthma attack.

  3. Spirometry - Wikipedia

    en.wikipedia.org/wiki/Spirometry

    Spirometry (meaning the measuring of breath) is the most common of the pulmonary function tests (PFTs). It measures lung function, specifically the amount (volume) and/or speed (flow) of air that can be inhaled and exhaled.

  4. Diffusing capacity for carbon monoxide - Wikipedia

    en.wikipedia.org/wiki/Diffusing_capacity_for...

    This test involves measuring the partial pressure difference between inspired and expired carbon monoxide. It relies on the strong affinity and large absorption capacity of red blood cells for carbon monoxide and thus demonstrates gas uptake by the capillaries that are less dependent on cardiac output. [3]

  5. Diffusing capacity - Wikipedia

    en.wikipedia.org/wiki/Diffusing_capacity

    Diffusing capacity of the lung (D L) (also known as transfer factor) measures the transfer of gas from air in the lung, to the red blood cells in lung blood vessels. It is part of a comprehensive series of pulmonary function tests to determine the overall ability of the lung to transport gas into and out of the blood.

  6. Peak expiratory flow - Wikipedia

    en.wikipedia.org/wiki/Peak_expiratory_flow

    To interpret the significance of peak expiratory flow measurements, a comparison is made to reference (normal, predicted) values based on measurements taken from the general population. Various reference values have been published in the literature and vary by population, ethnic group, age, sex, height and weight of the patient.

  7. Impulse oscillometry - Wikipedia

    en.wikipedia.org/wiki/Impulse_oscillometry

    Impulse oscillometry (IOS), also known as respiratory oscillometry, forced oscillatory technique (FOT), or just oscillometry, is a non-invasive lung function test that measures the mechanical properties of the respiratory system, particularly the upper and intrathoracic airways, lung tissue and chest wall, usually during the patient's tidal breathing (the way someone breathes when they are ...

  8. Oscar Predictions 2013 - The Huffington Post

    data.huffingtonpost.com/2013/01/oscar...

    Don't rely on bloviating pundits to tell you who'll prevail on Hollywood's big night. The Huffington Post crunched the stats on every Oscar nominee of the past 30 years to produce a scientific metric for predicting the winners at the 2013 Academy Awards.

  9. FEV1/FVC ratio - Wikipedia

    en.wikipedia.org/wiki/FEV1/FVC_ratio

    In obstructive lung disease, the FEV1 is reduced due to an obstruction of air escaping from the lungs. Thus, the FEV1/FVC ratio will be reduced. [4] More specifically, according to the National Institute for Clinical Excellence, the diagnosis of COPD is made when the FEV 1 /FVC ratio is less than 0.7 or [8] the FEV 1 is less than 75% of predicted; [9] however, other authoritative bodies have ...