Search results
Results from the WOW.Com Content Network
A common source of unintentional backfeeding is an electrical generator (typically a portable generator) that is improperly connected to a building electrical system.A properly installed electrical generator incorporates the use of a transfer switch or generator interlock kit to ensure the incoming electrical service line is disconnected when the generator is providing power to the building.
Tilting-disc inconel check valve Check valve symbol on piping and instrumentation diagrams.The arrow shows the flow direction. Vertical lift check valve. A check valve, non-return valve, reflux valve, retention valve, foot valve, or one-way valve is a valve that normally allows fluid (liquid or gas) to flow through it in only one direction.
Non-return or check valves allow the free flow of a fluid in one direction but prevent its flow in a reverse direction. They are often seen in drainage or sewage systems but may also be used in pressurized systems. Valves are available in several types, based on design and purpose: Gate, plug, or ball valves – Isolation; Globe valve ...
A dual check backflow preventer is similar to a double check valve in operation. It has two independent spring-loaded check valves. However, dual check valves usually do not include shutoff valves, may or may not be equipped with test cocks or ports, and is generally less reliable than a double check valve.
It is numbered with a stylized flag symbol surrounding the number (or sometimes a delta symbol). A general note applies generally and is not called out with flags. 2. Find number: "FN" meaning "find number" refers to the ordinal number that gives an ID tag to one of the constituents in a parts list (list of materials, bill of materials).
The flow resistance is defined, analogously to Ohm's law for electrical resistance, [2] as the ratio of applied pressure drop and resulting flow rate: R = Δ p Q {\displaystyle R={\frac {\Delta p}{Q}}} where Δ p {\displaystyle \Delta p} is the applied pressure difference between two ends of the conduit, and Q {\displaystyle Q} the flow rate.
Example of a single industrial control loop; showing continuously modulated control of process flow. Piping and instrumentation diagram of pump with storage tank. Symbols according to EN ISO 10628 and EN 62424. A more complex example of a P&ID. A piping and instrumentation diagram (P&ID) is defined as follows:
A mathematical prediction of the flow of electric power in a network, based on a model of the actual or proposed system; necessary for planning of electrical grids. load following power plant A power plant that can economically be operated over a significant range of output, so as to meet varying electric power demand. load-loss factor