Mass spectral interpretation is the method employed to identify the chemical formula, characteristic fragment patterns and possible fragment ions from the mass spectra. [1] [2] Mass spectra is a plot of relative abundance against mass-to-charge ratio. It is commonly used for the identification of organic compounds from electron ionization mass ...
Ion mobility spectrometry-mass spectrometry (IMS/MS or IMMS) is a technique where ions are first separated by drift time through some neutral gas under an applied electrical potential gradient before being introduced into a mass spectrometer. [43] Drift time is a measure of the collisional cross section relative to the charge of the ion.
A mass spectrum is a histogram plot of intensity vs. mass-to-charge ratio (m/z) in a chemical sample, [1] usually acquired using an instrument called a mass spectrometer. Not all mass spectra of a given substance are the same; for example, some mass spectrometers break the analyte molecules into fragments ; others observe the intact molecular ...
When a beam of high energy ions is used instead of atoms (as in secondary ion mass spectrometry), the method is known as liquid secondary ion mass spectrometry (LSIMS). [ 5 ] [ 6 ] [ 7 ] In FAB and LSIMS, the material to be analyzed is mixed with a non-volatile chemical protection environment, called a matrix , and is bombarded under vacuum ...
Chlorine dioxide is a chemical compound with the formula ClO 2 that exists as yellowish-green gas above 11 °C, a reddish-brown liquid between 11 °C and −59 °C, and as bright orange crystals below −59 °C. It is usually handled as an aqueous solution. It is commonly used as a bleach.
Chemical ionization (CI) is a soft ionization technique used in mass spectrometry. [ 1 ] [ 2 ] This was first introduced by Burnaby Munson and Frank H. Field in 1966. [ 3 ] This technique is a branch of gaseous ion-molecule chemistry. [ 2 ]
The mass spectrum can be used to determine the mass of the analytes, their elemental and isotopic composition, or to elucidate the chemical structure of the sample. [5] MS is an experiment that must take place in gas phase and under vacuum (1.33 * 10 −2 to 1.33 * 10 −6 pascal).
Sample preparation for mass spectrometry is used for the optimization of a sample for analysis in a mass spectrometer (MS). Each ionization method has certain factors that must be considered for that method to be successful, such as volume, concentration , sample phase, and composition of the analyte solution.