enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Micrometer (device) - Wikipedia

    en.wikipedia.org/wiki/Micrometer_(device)

    Tube micrometers have a cylindrical anvil positioned perpendicularly to a spindle and is used to measure the thickness of tubes. Micrometer stops are micrometer heads that are mounted on the table of a manual milling machine, bedways of a lathe, or other machine tool, in place of simple stops. They help the operator to position the table or ...

  3. Gauge block - Wikipedia

    en.wikipedia.org/wiki/Gauge_block

    They are used as a reference for the calibration of measuring equipment used in machine shops, such as micrometers, sine bars, calipers, and dial indicators (when used in an inspection role). Gauge blocks are the main means of length standardization used by industry.

  4. Snap gauge - Wikipedia

    en.wikipedia.org/wiki/Snap_gauge

    Snap go/no go gauge and indicator snap gauge. A snap gauge is a form of go/no go gauge.It is a limit gauge with permanently or temporarily fixed measurement aperture(s) (gaps) which is used to quickly verify whether an outside dimension of a part matches a preset dimension or falls within predefined tolerances.

  5. Precision measurement equipment laboratory - Wikipedia

    en.wikipedia.org/wiki/Precision_Measurement...

    The technicians who work in the PMEL will often specialize in one of these sections. The K-Sections are derived from the primary function of the TMDE. This is based upon the calibration authority. Most labs have three calibration sections divided into K1/K8, K5/K6 and K3/K4 that specialize in like test equipment.

  6. Bore gauge - Wikipedia

    en.wikipedia.org/wiki/Bore_gauge

    The gauge is then removed and measured with the aid of a micrometer anvil heads, move the head of the gauge around while making the measurement to ensure you get the maximum reading. Grasp the gauge near the head to aid in your maneuvering of the gauge while adjusting the micrometer so it just stops the gauge's motion at one spot only.

  7. Calibration - Wikipedia

    en.wikipedia.org/wiki/Calibration

    This is called a limited calibration. But if the final measurement requires 10% accuracy, then the 3% gauge never can be better than 3.3:1. Then perhaps adjusting the calibration tolerance for the gauge would be a better solution. If the calibration is performed at 100 units, the 1% standard would actually be anywhere between 99 and 101 units.

  8. Micrometer - Wikipedia

    en.wikipedia.org/wiki/Micrometer

    Download as PDF; Printable version; In other projects Wikidata item; Appearance. move to sidebar hide. Micrometer can mean: Micrometer (device), used for accurate ...

  9. Standard (metrology) - Wikipedia

    en.wikipedia.org/wiki/Standard_(metrology)

    A set of gauge blocks are used as a working standard to check the calibration of measurement tools such as micrometers.. An example of a primary standard was the international prototype of the kilogram (IPK) which was the master kilogram and the primary mass standard for the International System of Units (SI).